Inverter & HV Battery Compatibility Matrix
The manufacturer documents cover 156 inverter and battery combinations. An accessory is required for 36 of them. Find the inverter model to see which batteries it supports and which control modules it needs. Each entry links to its source. The meter and backup requirements and grid-code certificates are listed separately for the models they cover.
- Release declarations
- 175
- Declarations requiring an accessory
- 48
- System requirements
- 41
- Grid-code certificate PDFs
- 17
Residential inverter and battery pairings
| Inverter (power and phase) | Compatible HV battery | Release status | Accessory and conditions | Manufacturer document |
|---|---|---|---|---|
| GoodWe GW3.6K-EHA-G203.6 kW · Single-phase | GoodWe GW5.1-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW3.6K-EHA-G203.6 kW · Single-phase | GoodWe GW6.0-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW3.6K-EHA-G203.6 kW · Single-phase | GoodWe GW8.3-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW3.6K-EHA-G203.6 kW · Single-phase | GoodWe GW9.0-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW3K-EHA-G203 kW · Single-phase | GoodWe GW5.1-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW3K-EHA-G203 kW · Single-phase | GoodWe GW6.0-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW3K-EHA-G203 kW · Single-phase | GoodWe GW8.3-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW3K-EHA-G203 kW · Single-phase | GoodWe GW9.0-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW5K-EHA-G205 kW · Single-phase | GoodWe GW5.1-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW5K-EHA-G205 kW · Single-phase | GoodWe GW6.0-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW5K-EHA-G205 kW · Single-phase | GoodWe GW8.3-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW5K-EHA-G205 kW · Single-phase | GoodWe GW9.0-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW5K-ETA-G205 kW · Three-phase | GoodWe GW5.1-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW5K-ETA-G205 kW · Three-phase | GoodWe GW5.1-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW5K-ETA-G205 kW · Three-phase | GoodWe GW6.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW5K-ETA-G205 kW · Three-phase | GoodWe GW8.3-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW5K-ETA-G205 kW · Three-phase | GoodWe GW8.3-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW5K-ETA-G205 kW · Three-phase | GoodWe GW9.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW6K-EHA-G206 kW · Single-phase | GoodWe GW5.1-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW6K-EHA-G206 kW · Single-phase | GoodWe GW6.0-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW6K-EHA-G206 kW · Single-phase | GoodWe GW8.3-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW6K-EHA-G206 kW · Single-phase | GoodWe GW9.0-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW6K-ETA-G206 kW · Three-phase | GoodWe GW5.1-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW6K-ETA-G206 kW · Three-phase | GoodWe GW5.1-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW6K-ETA-G206 kW · Three-phase | GoodWe GW6.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW6K-ETA-G206 kW · Three-phase | GoodWe GW8.3-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW6K-ETA-G206 kW · Three-phase | GoodWe GW8.3-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW6K-ETA-G206 kW · Three-phase | GoodWe GW9.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW8K-EHA-G208 kW · Single-phase | GoodWe GW5.1-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW8K-EHA-G208 kW · Single-phase | GoodWe GW6.0-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW8K-EHA-G208 kW · Single-phase | GoodWe GW8.3-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW8K-EHA-G208 kW · Single-phase | GoodWe GW9.0-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW8K-ETA-G208 kW · Three-phase | GoodWe GW5.1-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW8K-ETA-G208 kW · Three-phase | GoodWe GW5.1-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW8K-ETA-G208 kW · Three-phase | GoodWe GW6.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW8K-ETA-G208 kW · Three-phase | GoodWe GW8.3-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW8K-ETA-G208 kW · Three-phase | GoodWe GW8.3-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW8K-ETA-G208 kW · Three-phase | GoodWe GW9.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW9.999K-ETA-G209.999 kW · Three-phase | GoodWe GW5.1-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW9.999K-ETA-G209.999 kW · Three-phase | GoodWe GW5.1-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW9.999K-ETA-G209.999 kW · Three-phase | GoodWe GW6.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW9.999K-ETA-G209.999 kW · Three-phase | GoodWe GW8.3-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW9.999K-ETA-G209.999 kW · Three-phase | GoodWe GW8.3-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW9.999K-ETA-G209.999 kW · Three-phase | GoodWe GW9.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW10K-EHA-G2010 kW · Single-phase | GoodWe GW5.1-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW10K-EHA-G2010 kW · Single-phase | GoodWe GW6.0-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW10K-EHA-G2010 kW · Single-phase | GoodWe GW8.3-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW10K-EHA-G2010 kW · Single-phase | GoodWe GW9.0-BAT-D-G20 | Released | The GoodWe ESA 3–10 kW datasheet (EMEA, p. 2–3) lists the GW5.1/8.3/6.0/9.0-BAT-D-G20 battery modules for the GW3K–10K-EHA-G20 power modules. The EMEA datasheet names the G20 modules for the single-phase ESA; the G21 variants are not in that table. | GoodWe ESA 3–10 kW – Datasheet (EMEA, V1.1) |
| GoodWe GW10K-ETA-G2010 kW · Three-phase | GoodWe GW5.1-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW10K-ETA-G2010 kW · Three-phase | GoodWe GW5.1-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW10K-ETA-G2010 kW · Three-phase | GoodWe GW6.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW10K-ETA-G2010 kW · Three-phase | GoodWe GW8.3-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW10K-ETA-G2010 kW · Three-phase | GoodWe GW8.3-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW10K-ETA-G2010 kW · Three-phase | GoodWe GW9.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW12K-ETA-G2012 kW · Three-phase | GoodWe GW5.1-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW12K-ETA-G2012 kW · Three-phase | GoodWe GW5.1-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW12K-ETA-G2012 kW · Three-phase | GoodWe GW6.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW12K-ETA-G2012 kW · Three-phase | GoodWe GW8.3-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW12K-ETA-G2012 kW · Three-phase | GoodWe GW8.3-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW12K-ETA-G2012 kW · Three-phase | GoodWe GW9.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW15K-ETA-G2015 kW · Three-phase | GoodWe GW5.1-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW15K-ETA-G2015 kW · Three-phase | GoodWe GW5.1-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW15K-ETA-G2015 kW · Three-phase | GoodWe GW6.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW15K-ETA-G2015 kW · Three-phase | GoodWe GW8.3-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW15K-ETA-G2015 kW · Three-phase | GoodWe GW8.3-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW15K-ETA-G2015 kW · Three-phase | GoodWe GW9.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW20K-ETA-G2020 kW · Three-phase | GoodWe GW5.1-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW20K-ETA-G2020 kW · Three-phase | GoodWe GW5.1-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW20K-ETA-G2020 kW · Three-phase | GoodWe GW6.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW20K-ETA-G2020 kW · Three-phase | GoodWe GW8.3-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW20K-ETA-G2020 kW · Three-phase | GoodWe GW8.3-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW20K-ETA-G2020 kW · Three-phase | GoodWe GW9.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW25K-ETA-G2025 kW · Three-phase | GoodWe GW5.1-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW25K-ETA-G2025 kW · Three-phase | GoodWe GW5.1-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW25K-ETA-G2025 kW · Three-phase | GoodWe GW6.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW25K-ETA-G2025 kW · Three-phase | GoodWe GW8.3-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW25K-ETA-G2025 kW · Three-phase | GoodWe GW8.3-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW25K-ETA-G2025 kW · Three-phase | GoodWe GW9.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW29.999K-ETA-G2029.999 kW · Three-phase | GoodWe GW5.1-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW29.999K-ETA-G2029.999 kW · Three-phase | GoodWe GW5.1-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW29.999K-ETA-G2029.999 kW · Three-phase | GoodWe GW6.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW29.999K-ETA-G2029.999 kW · Three-phase | GoodWe GW8.3-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW29.999K-ETA-G2029.999 kW · Three-phase | GoodWe GW8.3-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW29.999K-ETA-G2029.999 kW · Three-phase | GoodWe GW9.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW30K-ETA-G2030 kW · Three-phase | GoodWe GW5.1-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW30K-ETA-G2030 kW · Three-phase | GoodWe GW5.1-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW30K-ETA-G2030 kW · Three-phase | GoodWe GW6.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW30K-ETA-G2030 kW · Three-phase | GoodWe GW8.3-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW30K-ETA-G2030 kW · Three-phase | GoodWe GW8.3-BAT-D-G21 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW30K-ETA-G2030 kW · Three-phase | GoodWe GW9.0-BAT-D-G20 | Released | The GoodWe ESA datasheet lists GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries and names a battery expansion kit for higher capacity or a lower column (p. 79). | GoodWe ESA 5–30 kW – DatasheetGoodWe ESA 5–30 kW – User manual (V1.5) |
| SAJ H2-10K-T310 kW · Three-phase | SAJ B2-10.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet gives 179.2 to 230.4 V for the two-module B2-10.0; the H2 T3 manual's battery voltage range begins at 180 V. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-10K-T310 kW · Three-phase | SAJ B2-10.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-10K-T310 kW · Three-phase | SAJ B2-15.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-10K-T310 kW · Three-phase | SAJ B2-20.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-10K-T310 kW · Three-phase | SAJ B2-25.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-10K-T310 kW · Three-phase | SAJ BC2-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-10K-T310 kW · Three-phase | SAJ BU2-5.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system 2–5 battery modules One BU2-5.0 module alone operates at 89.6 to 115.2 V (SAJ's B2 datasheet gives this for the one-module B2-5.0), below the H2 T3's battery voltage range of 180 to 800 V; two modules operate at 179.2 to 230.4 V. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-10K-T310 kW · Three-phase | SAJ BU2-5.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-12K-T312 kW · Three-phase | SAJ B2-10.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-12K-T312 kW · Three-phase | SAJ B2-10.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet gives 179.2 to 230.4 V for the two-module B2-10.0; the H2 T3 manual's battery voltage range begins at 180 V. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-12K-T312 kW · Three-phase | SAJ B2-15.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-12K-T312 kW · Three-phase | SAJ B2-20.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-12K-T312 kW · Three-phase | SAJ B2-25.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-12K-T312 kW · Three-phase | SAJ BC2-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-12K-T312 kW · Three-phase | SAJ BU2-5.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-12K-T312 kW · Three-phase | SAJ BU2-5.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system 2–5 battery modules One BU2-5.0 module alone operates at 89.6 to 115.2 V (SAJ's B2 datasheet gives this for the one-module B2-5.0), below the H2 T3's battery voltage range of 180 to 800 V; two modules operate at 179.2 to 230.4 V. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-15K-T315 kW · Three-phase | SAJ B2-10.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-15K-T315 kW · Three-phase | SAJ B2-10.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet gives 179.2 to 230.4 V for the two-module B2-10.0; the H2 T3 manual's battery voltage range begins at 180 V. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-15K-T315 kW · Three-phase | SAJ B2-15.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-15K-T315 kW · Three-phase | SAJ B2-20.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-15K-T315 kW · Three-phase | SAJ B2-25.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-15K-T315 kW · Three-phase | SAJ BC2-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-15K-T315 kW · Three-phase | SAJ BU2-5.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-15K-T315 kW · Three-phase | SAJ BU2-5.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system 2–5 battery modules One BU2-5.0 module alone operates at 89.6 to 115.2 V (SAJ's B2 datasheet gives this for the one-module B2-5.0), below the H2 T3's battery voltage range of 180 to 800 V; two modules operate at 179.2 to 230.4 V. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-20K-T320 kW · Three-phase | SAJ B2-10.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-20K-T320 kW · Three-phase | SAJ B2-10.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet gives 179.2 to 230.4 V for the two-module B2-10.0; the H2 T3 manual's battery voltage range begins at 180 V. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-20K-T320 kW · Three-phase | SAJ B2-15.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-20K-T320 kW · Three-phase | SAJ B2-20.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-20K-T320 kW · Three-phase | SAJ B2-25.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-20K-T320 kW · Three-phase | SAJ BC2-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-20K-T320 kW · Three-phase | SAJ BU2-5.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system 2–5 battery modules One BU2-5.0 module alone operates at 89.6 to 115.2 V (SAJ's B2 datasheet gives this for the one-module B2-5.0), below the H2 T3's battery voltage range of 180 to 800 V; two modules operate at 179.2 to 230.4 V. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-20K-T320 kW · Three-phase | SAJ BU2-5.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-25K-T325 kW · Three-phase | SAJ B2-10.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-25K-T325 kW · Three-phase | SAJ B2-10.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet gives 179.2 to 230.4 V for the two-module B2-10.0; the H2 T3 manual's battery voltage range begins at 180 V. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-25K-T325 kW · Three-phase | SAJ B2-15.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-25K-T325 kW · Three-phase | SAJ B2-20.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-25K-T325 kW · Three-phase | SAJ B2-25.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-25K-T325 kW · Three-phase | SAJ BC2-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-25K-T325 kW · Three-phase | SAJ BU2-5.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system 2–5 battery modules One BU2-5.0 module alone operates at 89.6 to 115.2 V (SAJ's B2 datasheet gives this for the one-module B2-5.0), below the H2 T3's battery voltage range of 180 to 800 V; two modules operate at 179.2 to 230.4 V. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-25K-T325 kW · Three-phase | SAJ BU2-5.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-30K-T3-DE29.999 kW · Three-phase | SAJ B2-10.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-30K-T3-DE29.999 kW · Three-phase | SAJ B2-10.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet gives 179.2 to 230.4 V for the two-module B2-10.0; the H2 T3 manual's battery voltage range begins at 180 V. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-30K-T3-DE29.999 kW · Three-phase | SAJ B2-15.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-30K-T3-DE29.999 kW · Three-phase | SAJ B2-20.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-30K-T3-DE29.999 kW · Three-phase | SAJ B2-25.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-30K-T3-DE29.999 kW · Three-phase | SAJ BC2-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-30K-T3-DE29.999 kW · Three-phase | SAJ BU2-5.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product. SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ H2-30K-T3-DE29.999 kW · Three-phase | SAJ BU2-5.0-HV1 | Accessory required | SAJ BC2-HV1 × 1 per system 2–5 battery modules One BU2-5.0 module alone operates at 89.6 to 115.2 V (SAJ's B2 datasheet gives this for the one-module B2-5.0), below the H2 T3's battery voltage range of 180 to 800 V; two modules operate at 179.2 to 230.4 V. | SAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – User manual (5.0–25.0 kWh)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2SAJ H2 10–30K T2/T3 – User manual, p. 37 |
| SAJ HS2-5K-T2-X5 kW · Three-phase | SAJ BU2-5.0-HV1 | Released | 2–5 battery modules The HS2 takes two to five BU2-5.0 battery modules (HS2/AS2 manual V0.3, PDF p12). Battery voltage range 180 to 600 V. | SAJ HS2/AS2 5–10K-T2 – User manual (HS2-5K to HS2-10K-T2, V0.3), p. 12SAJ HS2 – Three-phase storage system datasheetSAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2 |
| SAJ HS2-5K-T2-X5 kW · Three-phase | SAJ BU2-5.0-HV1 | Released | 2–5 battery modules One BU2-5.0 module alone operates at 89.6 to 115.2 V (SAJ's B2 datasheet gives this for the one-module B2-5.0), below the HS2's battery voltage range of 180 to 600 V; the HS2 manual gives two modules as the smallest stack. | SAJ HS2/AS2 5–10K-T2 – User manual (HS2-5K to HS2-10K-T2, V0.3), p. 12SAJ HS2 – Three-phase storage system datasheetSAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2 |
| SAJ HS2-6K-T2-X6 kW · Three-phase | SAJ BU2-5.0-HV1 | Released | 2–5 battery modules The HS2 takes two to five BU2-5.0 battery modules (HS2/AS2 manual V0.3, PDF p12). Battery voltage range 180 to 600 V. | SAJ HS2/AS2 5–10K-T2 – User manual (HS2-5K to HS2-10K-T2, V0.3), p. 12SAJ HS2 – Three-phase storage system datasheetSAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2 |
| SAJ HS2-6K-T2-X6 kW · Three-phase | SAJ BU2-5.0-HV1 | Released | 2–5 battery modules One BU2-5.0 module alone operates at 89.6 to 115.2 V (SAJ's B2 datasheet gives this for the one-module B2-5.0), below the HS2's battery voltage range of 180 to 600 V; the HS2 manual gives two modules as the smallest stack. | SAJ HS2/AS2 5–10K-T2 – User manual (HS2-5K to HS2-10K-T2, V0.3), p. 12SAJ HS2 – Three-phase storage system datasheetSAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2 |
| SAJ HS2-8K-T2-X8 kW · Three-phase | SAJ BU2-5.0-HV1 | Released | 2–5 battery modules The HS2 takes two to five BU2-5.0 battery modules (HS2/AS2 manual V0.3, PDF p12). Battery voltage range 180 to 600 V. | SAJ HS2/AS2 5–10K-T2 – User manual (HS2-5K to HS2-10K-T2, V0.3), p. 12SAJ HS2 – Three-phase storage system datasheetSAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2 |
| SAJ HS2-8K-T2-X8 kW · Three-phase | SAJ BU2-5.0-HV1 | Released | 2–5 battery modules One BU2-5.0 module alone operates at 89.6 to 115.2 V (SAJ's B2 datasheet gives this for the one-module B2-5.0), below the HS2's battery voltage range of 180 to 600 V; the HS2 manual gives two modules as the smallest stack. | SAJ HS2/AS2 5–10K-T2 – User manual (HS2-5K to HS2-10K-T2, V0.3), p. 12SAJ HS2 – Three-phase storage system datasheetSAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2 |
| SAJ HS2-10K-T2-X10 kW · Three-phase | SAJ BU2-5.0-HV1 | Released | 2–5 battery modules The HS2 takes two to five BU2-5.0 battery modules (HS2/AS2 manual V0.3, PDF p12). Battery voltage range 180 to 600 V. | SAJ HS2/AS2 5–10K-T2 – User manual (HS2-5K to HS2-10K-T2, V0.3), p. 12SAJ HS2 – Three-phase storage system datasheetSAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2 |
| SAJ HS2-10K-T2-X10 kW · Three-phase | SAJ BU2-5.0-HV1 | Released | 2–5 battery modules One BU2-5.0 module alone operates at 89.6 to 115.2 V (SAJ's B2 datasheet gives this for the one-module B2-5.0), below the HS2's battery voltage range of 180 to 600 V; the HS2 manual gives two modules as the smallest stack. | SAJ HS2/AS2 5–10K-T2 – User manual (HS2-5K to HS2-10K-T2, V0.3), p. 12SAJ HS2 – Three-phase storage system datasheetSAJ H2, HS2, HS3 – Configuration instructions (V1.0)SAJ B2 HV1/HV5 – Datasheet (BEU, 5.0–25.0 kWh), p. 2 |
| SAJ HS3-5K-T2-W/G-PX5 kW · Three-phase | SAJ BU3-5.0-TV2-PRO | Released | 1–8 battery modules BU3-5.0-TV2-PRO modules, 1 to 8 per inverter (450 V nominal, 380-500 V window matching the HS3 battery port exactly). | SAJ HS3 5–12K-T2 – Three-phase storage system datasheet (EU) |
| SAJ HS3-6K-T2-W/G-PX6 kW · Three-phase | SAJ BU3-5.0-TV2-PRO | Released | 1–8 battery modules BU3-5.0-TV2-PRO modules, 1 to 8 per inverter (450 V nominal, 380-500 V window matching the HS3 battery port exactly). | SAJ HS3 5–12K-T2 – Three-phase storage system datasheet (EU) |
| SAJ HS3-8K-T2-W/G-PX8 kW · Three-phase | SAJ BU3-5.0-TV2-PRO | Released | 1–8 battery modules BU3-5.0-TV2-PRO modules, 1 to 8 per inverter (450 V nominal, 380-500 V window matching the HS3 battery port exactly). | SAJ HS3 5–12K-T2 – Three-phase storage system datasheet (EU) |
| SAJ HS3-10K-T2-W/G-PX10 kW · Three-phase | SAJ BU3-5.0-TV2-PRO | Released | 1–8 battery modules BU3-5.0-TV2-PRO modules, 1 to 8 per inverter (450 V nominal, 380-500 V window matching the HS3 battery port exactly). | SAJ HS3 5–12K-T2 – Three-phase storage system datasheet (EU) |
| SAJ HS3-12K-T2-W/G-PX12 kW · Three-phase | SAJ BU3-5.0-TV2-PRO | Released | 1–8 battery modules BU3-5.0-TV2-PRO modules, 1 to 8 per inverter (450 V nominal, 380-500 V window matching the HS3 battery port exactly). | SAJ HS3 5–12K-T2 – Three-phase storage system datasheet (EU) |
Commercial and industrial pairings
| Inverter (power and phase) | Compatible HV battery | Release status | Accessory and conditions | Manufacturer document |
|---|---|---|---|---|
| GoodWe GW50K-ET-1050 kW · Three-phase | GoodWe GW61.4-BAT-AC-G10 | Released | GoodWe's Battery Compatibility Overview (p. 6) lists GW61.4-BAT-AC-G10 for the ET (40–50 kW) series and requires inverter firmware ARM 10 or later. Battery charge/discharge power equals battery working voltage × min(battery current, 100 A). | GoodWe EMEA – Battery compatibility overview, p. 6 |
| GoodWe GW50K-ET-1050 kW · Three-phase | GoodWe GW112.6-BAT-AC-G10 | Released | GoodWe's Battery Compatibility Overview (p. 6) lists GW112.6-BAT-AC-G10 for the ET (40–50 kW) series and requires inverter firmware ARM 10 or later. Battery charge/discharge power equals battery working voltage × min(battery current, 100 A). | GoodWe EMEA – Battery compatibility overview, p. 6 |
| GoodWe GW50K-ET-1050 kW · Three-phase | GoodWe LX C101-10 | Released | 11–11 battery modules GoodWe's Battery Compatibility Overview (p. 6) lists LX C101-10 to LX C156-10 in its ET (40–50 kW) column; up to 3 identical Lynx C cabinets can be paralleled on one ET 40–50 kW battery input (Lynx C User Manual, p. 23). Footnote 2 on page 6 states that the ET 50 kW inverter with a single LX C101-10 (422.4 V nominal, 42.24 kW at 100 A) cannot reach the inverter's maximum 50 kW power. For use with ET 40–50 kW, the Lynx C cabinet requires BMS version 25600 or later (date in the serial number: 1 June 2024 or later). The stated DC power is at nominal voltage. Available power varies with battery temperature and state of charge. | GoodWe EMEA – Battery compatibility overview, p. 6GoodWe Lynx C 101–156 kWh User Manual V1.3 (EN), p. 23GoodWe ET 25–50 kW Commercial Smart Inverter Solutions User Manual (EN), p. 3GoodWe Lynx C Series 101–156 kWh Datasheet (EMEA, EN), p. 2 |
| GoodWe GW50K-ET-1050 kW · Three-phase | GoodWe LX C138-10 | Released | 15–15 battery modules GoodWe's Battery Compatibility Overview (p. 6) lists LX C138-10 in its ET (40–50 kW) column; at 576.0 V nominal voltage and 100 A (57.60 kW), a single cabinet supports full 50 kW inverter output, and up to 3 identical cabinets can be paralleled (Lynx C User Manual, p. 23). For use with ET 40–50 kW, the Lynx C cabinet requires BMS version 25600 or later (date in the serial number: 1 June 2024 or later). The stated DC power is at nominal voltage. Available power varies with battery temperature and state of charge. | GoodWe EMEA – Battery compatibility overview, p. 6GoodWe Lynx C 101–156 kWh User Manual V1.3 (EN), p. 23GoodWe ET 25–50 kW Commercial Smart Inverter Solutions User Manual (EN), p. 3GoodWe Lynx C Series 101–156 kWh Datasheet (EMEA, EN), p. 2 |
| GoodWe GW50K-ET-1050 kW · Three-phase | GoodWe LX C156-10 | Released | 17–17 battery modules GoodWe's Battery Compatibility Overview (p. 6) lists LX C156-10 in its ET (40–50 kW) column; at 652.8 V nominal voltage and 100 A (65.28 kW), a single cabinet supports full 50 kW inverter output, and up to 3 identical cabinets can be paralleled (Lynx C User Manual, p. 23). For use with ET 40–50 kW, the Lynx C cabinet requires BMS version 25600 or later (date in the serial number: 1 June 2024 or later). The stated DC power is at nominal voltage. Available power varies with battery temperature and state of charge. | GoodWe EMEA – Battery compatibility overview, p. 6GoodWe Lynx C 101–156 kWh User Manual V1.3 (EN), p. 23GoodWe ET 25–50 kW Commercial Smart Inverter Solutions User Manual (EN), p. 3GoodWe Lynx C Series 101–156 kWh Datasheet (EMEA, EN), p. 2 |
| GoodWe GW80K-ET-G1080 kW · Three-phase | GoodWe GW61.4-BAT-AC-G10 | Released | The Battery Compatibility Overview (p. 6) states that GW61.4-BAT-AC-G10 paired with ET (80–100 kW) cannot reach the inverter's full power output. GoodWe's BAT-C datasheet (p. 2) gives the GW61.4-BAT-AC-G10 an operating voltage range of 275.52 to 346.56 V (nominal 307.2 V); the ET 75–100 kW datasheet (p. 2) gives a battery voltage range of 300 to 800 V and a start-up voltage of 300 V. | GoodWe EMEA – Battery compatibility overviewGoodWe BAT-AC-G10 – Inverter compatibility statementGoodWe BAT-C 61.4–112.6 kWh – Datasheet (EMEA)GoodWe ET 75–100 kW – Datasheet (EMEA, V2.1) |
| GoodWe GW80K-ET-G1080 kW · Three-phase | GoodWe GW61.4-BAT-AC-G10 | Released | Two GoodWe documents carry this pair: the Battery Compatibility Overview, ET (80–100 kW) column, and a signed Compatibility Statement of 2025-04-07 naming GW80K-ET-G10, GW99.99K-ET-G10 and GW100K-ET-G10 against GW61.4 to GW112.6-BAT-AC-G10. | GoodWe EMEA – Battery compatibility overviewGoodWe BAT-AC-G10 – Inverter compatibility statementGoodWe BAT-C 61.4–112.6 kWh – Datasheet (EMEA)GoodWe ET 75–100 kW – Datasheet (EMEA, V2.1) |
| GoodWe GW80K-ET-G1080 kW · Three-phase | GoodWe GW112.6-BAT-AC-G10 | Released | Two GoodWe documents carry this pair: the Battery Compatibility Overview, ET (80–100 kW) column, and a signed Compatibility Statement of 2025-04-07 naming GW80K-ET-G10, GW99.99K-ET-G10 and GW100K-ET-G10 against GW61.4 to GW112.6-BAT-AC-G10. | GoodWe EMEA – Battery compatibility overviewGoodWe BAT-AC-G10 – Inverter compatibility statementGoodWe BAT-C 61.4–112.6 kWh – Datasheet (EMEA)GoodWe ET 75–100 kW – Datasheet (EMEA, V2.1) |
| GoodWe GW80K-ET-G1080 kW · Three-phase | GoodWe GW208.9-BAT-LC-G10 | Released | GoodWe's Battery Compatibility Overview (p. 6) lists GW208.9-BAT-LC-G10 in its ET (80–100 kW) column. | GoodWe EMEA – Battery compatibility overview |
| GoodWe GW80K-ETR-G1080 kW · Three-phase | GoodWe GW261.2-BAT-LCD-G10 | Released | GoodWe's Battery Compatibility Overview (p. 6) lists GW261.2-BAT-LCD-G10 in its ETR 80–125 kW column, which covers the GW80K/99.99K/100K/110K/124.99K-ETR-G10 models. The ETR 80–125 kW datasheet (EMEA, p. 2) prints that series; the user manual's single-unit and parallel tables list the battery for the series. | GoodWe EMEA – Battery compatibility overviewGoodWe ETR 80–125 kW – Datasheet (EMEA, V1.1)GoodWe ETR 50–125 kW – User manual |
| GoodWe GW99.99K-ET-G1099.99 kW · Three-phase | GoodWe GW61.4-BAT-AC-G10 | Released | Two GoodWe documents carry this pair: the Battery Compatibility Overview, ET (80–100 kW) column, and a signed Compatibility Statement of 2025-04-07 naming GW80K-ET-G10, GW99.99K-ET-G10 and GW100K-ET-G10 against GW61.4 to GW112.6-BAT-AC-G10. | GoodWe EMEA – Battery compatibility overviewGoodWe BAT-AC-G10 – Inverter compatibility statementGoodWe BAT-C 61.4–112.6 kWh – Datasheet (EMEA)GoodWe ET 75–100 kW – Datasheet (EMEA, V2.1) |
| GoodWe GW99.99K-ET-G1099.99 kW · Three-phase | GoodWe GW61.4-BAT-AC-G10 | Released | The Battery Compatibility Overview (p. 6) states that GW61.4-BAT-AC-G10 paired with ET (80–100 kW) cannot reach the inverter's full power output. GoodWe's BAT-C datasheet (p. 2) gives the GW61.4-BAT-AC-G10 an operating voltage range of 275.52 to 346.56 V (nominal 307.2 V); the ET 75–100 kW datasheet (p. 2) gives a battery voltage range of 300 to 800 V and a start-up voltage of 300 V. | GoodWe EMEA – Battery compatibility overviewGoodWe BAT-AC-G10 – Inverter compatibility statementGoodWe BAT-C 61.4–112.6 kWh – Datasheet (EMEA)GoodWe ET 75–100 kW – Datasheet (EMEA, V2.1) |
| GoodWe GW99.99K-ET-G1099.99 kW · Three-phase | GoodWe GW112.6-BAT-AC-G10 | Released | Two GoodWe documents carry this pair: the Battery Compatibility Overview, ET (80–100 kW) column, and a signed Compatibility Statement of 2025-04-07 naming GW80K-ET-G10, GW99.99K-ET-G10 and GW100K-ET-G10 against GW61.4 to GW112.6-BAT-AC-G10. | GoodWe EMEA – Battery compatibility overviewGoodWe BAT-AC-G10 – Inverter compatibility statementGoodWe BAT-C 61.4–112.6 kWh – Datasheet (EMEA)GoodWe ET 75–100 kW – Datasheet (EMEA, V2.1) |
| GoodWe GW99.99K-ET-G1099.99 kW · Three-phase | GoodWe GW208.9-BAT-LC-G10 | Released | GoodWe's Battery Compatibility Overview (p. 6) lists GW208.9-BAT-LC-G10 in its ET (80–100 kW) column. | GoodWe EMEA – Battery compatibility overview |
| GoodWe GW99.99K-ETR-G1099.99 kW · Three-phase | GoodWe GW261.2-BAT-LCD-G10 | Released | GoodWe's Battery Compatibility Overview (p. 6) lists GW261.2-BAT-LCD-G10 in its ETR 80–125 kW column, which covers the GW80K/99.99K/100K/110K/124.99K-ETR-G10 models. The ETR 80–125 kW datasheet (EMEA, p. 2) prints that series; the user manual's single-unit and parallel tables list the battery for the series. | GoodWe EMEA – Battery compatibility overviewGoodWe ETR 80–125 kW – Datasheet (EMEA, V1.1)GoodWe ETR 50–125 kW – User manual |
| GoodWe GW100K-ET-G10100 kW · Three-phase | GoodWe GW61.4-BAT-AC-G10 | Released | The Battery Compatibility Overview (p. 6) states that GW61.4-BAT-AC-G10 paired with ET (80–100 kW) cannot reach the inverter's full power output. GoodWe's BAT-C datasheet (p. 2) gives the GW61.4-BAT-AC-G10 an operating voltage range of 275.52 to 346.56 V (nominal 307.2 V); the ET 75–100 kW datasheet (p. 2) gives a battery voltage range of 300 to 800 V and a start-up voltage of 300 V. | GoodWe EMEA – Battery compatibility overviewGoodWe BAT-AC-G10 – Inverter compatibility statementGoodWe BAT-C 61.4–112.6 kWh – Datasheet (EMEA)GoodWe ET 75–100 kW – Datasheet (EMEA, V2.1) |
| GoodWe GW100K-ET-G10100 kW · Three-phase | GoodWe GW61.4-BAT-AC-G10 | Released | Two GoodWe documents carry this pair: the Battery Compatibility Overview, ET (80–100 kW) column, and a signed Compatibility Statement of 2025-04-07 naming GW80K-ET-G10, GW99.99K-ET-G10 and GW100K-ET-G10 against GW61.4 to GW112.6-BAT-AC-G10. | GoodWe EMEA – Battery compatibility overviewGoodWe BAT-AC-G10 – Inverter compatibility statementGoodWe BAT-C 61.4–112.6 kWh – Datasheet (EMEA)GoodWe ET 75–100 kW – Datasheet (EMEA, V2.1) |
| GoodWe GW100K-ET-G10100 kW · Three-phase | GoodWe GW112.6-BAT-AC-G10 | Released | Two GoodWe documents carry this pair: the Battery Compatibility Overview, ET (80–100 kW) column, and a signed Compatibility Statement of 2025-04-07 naming GW80K-ET-G10, GW99.99K-ET-G10 and GW100K-ET-G10 against GW61.4 to GW112.6-BAT-AC-G10. | GoodWe EMEA – Battery compatibility overviewGoodWe BAT-AC-G10 – Inverter compatibility statementGoodWe BAT-C 61.4–112.6 kWh – Datasheet (EMEA)GoodWe ET 75–100 kW – Datasheet (EMEA, V2.1) |
| GoodWe GW100K-ET-G10100 kW · Three-phase | GoodWe GW208.9-BAT-LC-G10 | Released | GoodWe's Battery Compatibility Overview (p. 6) lists GW208.9-BAT-LC-G10 in its ET (80–100 kW) column. | GoodWe EMEA – Battery compatibility overview |
| GoodWe GW100K-ETR-G10100 kW · Three-phase | GoodWe GW261.2-BAT-LCD-G10 | Released | GoodWe's Battery Compatibility Overview (p. 6) lists GW261.2-BAT-LCD-G10 in its ETR 80–125 kW column, which covers the GW80K/99.99K/100K/110K/124.99K-ETR-G10 models. The ETR 80–125 kW datasheet (EMEA, p. 2) prints that series; the user manual's single-unit and parallel tables list the battery for the series. | GoodWe EMEA – Battery compatibility overviewGoodWe ETR 80–125 kW – Datasheet (EMEA, V1.1)GoodWe ETR 50–125 kW – User manual |
| GoodWe GW110K-ETR-G10110 kW · Three-phase | GoodWe GW261.2-BAT-LCD-G10 | Released | GoodWe's Battery Compatibility Overview (p. 6) lists GW261.2-BAT-LCD-G10 in its ETR 80–125 kW column, which covers the GW80K/99.99K/100K/110K/124.99K-ETR-G10 models. The ETR 80–125 kW datasheet (EMEA, p. 2) prints that series; the user manual's single-unit and parallel tables list the battery for the series. | GoodWe EMEA – Battery compatibility overviewGoodWe ETR 80–125 kW – Datasheet (EMEA, V1.1)GoodWe ETR 50–125 kW – User manual |
| GoodWe GW124.99K-ETR-G10124.99 kW · Three-phase | GoodWe GW261.2-BAT-LCD-G10 | Released | GoodWe's Battery Compatibility Overview (p. 6) lists GW261.2-BAT-LCD-G10 in its ETR 80–125 kW column, which covers the GW80K/99.99K/100K/110K/124.99K-ETR-G10 models. The ETR 80–125 kW datasheet (EMEA, p. 2) prints that series; the user manual's single-unit and parallel tables list the battery for the series. | GoodWe EMEA – Battery compatibility overviewGoodWe ETR 80–125 kW – Datasheet (EMEA, V1.1)GoodWe ETR 50–125 kW – User manual |
| GoodWe GW125K-ETR-G10125 kW · Three-phase | GoodWe GW208.9-BAT-LCD-G10 | Released | Listed one-way: a cited document from GoodWe (ETR 50–125 kW) lists the pair; a cited document from GoodWe Battery Compatibility Overview does not. The GoodWe ETR 50–125 kW user manual (pp. 24–25) lists GW125K-ETR-G10 with GW208.9-BAT-LCD-G10 in its single-unit system table; pp. 26–27 repeat the pair for parallel systems, which require SEC3000C main program V7.8.19 or later. GoodWe's Battery Compatibility Overview (p. 6) does not name GW208.9-BAT-LCD-G10, so the manual's system table is not a complete warranty approval. GoodWe's Battery Compatibility Overview (p. 1) approves only the batteries it lists for connection under the GoodWe Limited Warranty. GW208.9-BAT-LCD-G10 is absent from its ETR 80–125 kW matrix on p. 6. | GoodWe ETR 50–125 kW – User manualGoodWe EMEA – Battery compatibility overview |
| GoodWe GW125K-ETR-G10125 kW · Three-phase | GoodWe GW261.2-BAT-LCD-G10 | Released | GoodWe's Battery Compatibility Overview (p. 6) lists GW261.2-BAT-LCD-G10 in its ETR 80–125 kW column, and the GoodWe ETR 80–125 kW datasheet (EMEA, p. 2) names GW125K-ETR-G10 in that series. The GoodWe ETR 50–125 kW user manual (pp. 24–27) lists both models in its single-unit and parallel system tables; parallel systems require SEC3000C main program V7.8.19 or later. The datasheet (p. 3, footnote 4) requires a PV-string open-circuit input voltage above 813 V when this battery is connected. | GoodWe EMEA – Battery compatibility overviewGoodWe ETR 80–125 kW – Datasheet (EMEA, V1.1)GoodWe ETR 50–125 kW – User manual |
Meters, backup switches and parallel controllers
| Inverter | Accessory role | Scope | Accessory and conditions | Manufacturer document |
|---|---|---|---|---|
| GoodWe GW5K-ETA-G20 | Smart meter | Included | The ESA's ETA inverter has a built-in meter and includes its CT (120 A:40 mA); a GM330 or GMK330 is added where the built-in meter is not sufficient (ESA manual, PDF p. 34). | GoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW6K-ETA-G20 | Smart meter | Included | The ESA's ETA inverter has a built-in meter and includes its CT (120 A:40 mA); a GM330 or GMK330 is added where the built-in meter is not sufficient (ESA manual, PDF p. 34). | GoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW8K-ETA-G20 | Smart meter | Included | The ESA's ETA inverter has a built-in meter and includes its CT (120 A:40 mA); a GM330 or GMK330 is added where the built-in meter is not sufficient (ESA manual, PDF p. 34). | GoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW9.999K-ETA-G20 | Smart meter | Included | The ESA's ETA inverter has a built-in meter and includes its CT (120 A:40 mA); a GM330 or GMK330 is added where the built-in meter is not sufficient (ESA manual, PDF p. 34). | GoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW10K-ETA-G20 | Smart meter | Included | The ESA's ETA inverter has a built-in meter and includes its CT (120 A:40 mA); a GM330 or GMK330 is added where the built-in meter is not sufficient (ESA manual, PDF p. 34). | GoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW12K-ETA-G20 | Smart meter | Included | The ESA's ETA inverter has a built-in meter and includes its CT (120 A:40 mA); a GM330 or GMK330 is added where the built-in meter is not sufficient (ESA manual, PDF p. 34). | GoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW15K-ETA-G20 | Smart meter | Included | The ESA's ETA inverter has a built-in meter and includes its CT (120 A:40 mA); a GM330 or GMK330 is added where the built-in meter is not sufficient (ESA manual, PDF p. 34). | GoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW20K-ETA-G20 | Smart meter | Included | The ESA's ETA inverter has a built-in meter and includes its CT (120 A:40 mA); a GM330 or GMK330 is added where the built-in meter is not sufficient (ESA manual, PDF p. 34). | GoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW25K-ETA-G20 | Smart meter | Included | The ESA's ETA inverter has a built-in meter and includes its CT (120 A:40 mA); a GM330 or GMK330 is added where the built-in meter is not sufficient (ESA manual, PDF p. 34). | GoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW29.999K-ETA-G20 | Smart meter | Included | The ESA's ETA inverter has a built-in meter and includes its CT (120 A:40 mA); a GM330 or GMK330 is added where the built-in meter is not sufficient (ESA manual, PDF p. 34). | GoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW30K-ETA-G20 | Smart meter | Included | The ESA's ETA inverter has a built-in meter and includes its CT (120 A:40 mA); a GM330 or GMK330 is added where the built-in meter is not sufficient (ESA manual, PDF p. 34). | GoodWe ESA 5–30 kW – User manual (V1.5) |
| GoodWe GW50K-ET-10 | Backup switch | Supplied separately | Single-inverter backup requires a separately supplied GoodWe STS200-80-10 with cabinet software version 4.400 or later. With this cabinet, transfer takes less than 10 ms when the backup load is below the inverter’s 50 kW rated power. Nominal backup apparent power is 50 kVA. | GoodWe ET 25–50 kW Commercial Smart Inverter Solutions User Manual (EN), p. 3GoodWe ET 25–50 kW Commercial Smart Inverter Solutions User Manual (EN), p. 31GoodWe ET 25–50 kW Commercial Smart Inverter Solutions User Manual (EN), p. 112GoodWe ET50 Series 40–50 kW Datasheet V1.1 (EMEA, EN), p. 2 |
| GoodWe GW50K-ET-10 | Parallel controller | Supplied separately | GoodWe SEC3000C × 1 per system Up to 10 GW40K-ET-10 / GW50K-ET-10 inverters can operate in parallel via one SEC3000C controller, with each inverter equipped with a WiFi/LAN Kit-20 module (Solutions Manual, pp. 4, 30, 32, and 113). All paralleled inverters require identical firmware at ARM 11.475 or later and DSP 4.400 or later, and cannot be paralleled with ET 100 kW or ESA 261 kWh units (IoT Compatibility List V18, p. 9). | GoodWe ET 25–50 kW Commercial Smart Inverter Solutions User Manual (EN), p. 30GoodWe ET 25–50 kW Commercial Smart Inverter Solutions User Manual (EN), p. 32GoodWe IoT – Inverter and IoT device compatibility (V18), p. 9GoodWe ET 25–50 kW Commercial Smart Inverter Solutions User Manual (EN), p. 4GoodWe ET 25–50 kW Commercial Smart Inverter Solutions User Manual (EN), p. 113 |
| GoodWe GW50K-ET-10 | Smart meter | Included | A GoodWe smart meter (GM330 or GM3000) is supplied with the GW50K-ET-10 for single-inverter operation (User Manual, pp. 11 and 31; Solutions Manual, p. 32). When using the GM330, external current transformers with a 5 A secondary (nA/5A, 200 to 5000 A primary) are provided separately. | GoodWe ET 40–50 kW Hybrid Inverter User Manual V1.0 (EN), p. 11GoodWe ET 40–50 kW Hybrid Inverter User Manual V1.0 (EN), p. 31GoodWe ET 25–50 kW Commercial Smart Inverter Solutions User Manual (EN), p. 32 |
| GoodWe GW80K-ET-G10 | Parallel controller | Supplied separately | GoodWe SEC3000C × 1 per system The SEC3000C is optional for this grid-connected LAN configuration. If you select it, check the firmware on site before commissioning. The ET manual specifies SEC main program V7.5.32 or later. The SEC manual specifies WiFi/LAN Kit-20 V2.5.49 or later. | GoodWe ET 50–100 kW – User manual (V1.2), p. 30GoodWe ET 50–100 kW – User manual (V1.2), p. 32GoodWe SEC3000C – User manual, p. 41GoodWe SEC3000C – User manual, p. 54GoodWe SEC3000C – Datasheet (EMEA), p. 1 |
| GoodWe GW80K-ET-G10 | Smart meter | Included | The ET 80 to 100 kW includes a GM330 smart meter for a single-unit system; its CTs (nA/5A, 200 to 5000 A primary) are bought separately (ET 50-100 kW manual, PDF pp. 12 and 19). | GoodWe ET 50–100 kW – System manual (V1.3) |
| GoodWe GW80K-ETR-G10 | Parallel controller | Supplied separately | GoodWe SEC3000C × 1 per system The GoodWe ETR 50-125 kW user manual (pp. 26-27) repeats the pairs for parallel systems, which require SEC3000C main program V7.8.19 or later: one SEC3000C coordinates the parallel system. | GoodWe ETR 50–125 kW – User manual |
| GoodWe GW99.99K-ET-G10 | Parallel controller | Supplied separately | GoodWe SEC3000C × 1 per system The SEC3000C is optional for this grid-connected LAN configuration. If you select it, check the firmware on site before commissioning. The ET manual specifies SEC main program V7.5.32 or later. The SEC manual specifies WiFi/LAN Kit-20 V2.5.49 or later. | GoodWe ET 50–100 kW – User manual (V1.2), p. 30GoodWe ET 50–100 kW – User manual (V1.2), p. 32GoodWe SEC3000C – User manual, p. 41GoodWe SEC3000C – User manual, p. 54GoodWe SEC3000C – Datasheet (EMEA), p. 1 |
| GoodWe GW99.99K-ET-G10 | Smart meter | Included | The ET 80 to 100 kW includes a GM330 smart meter for a single-unit system; its CTs (nA/5A, 200 to 5000 A primary) are bought separately (ET 50-100 kW manual, PDF pp. 12 and 19). | GoodWe ET 50–100 kW – System manual (V1.3) |
| GoodWe GW99.99K-ETR-G10 | Parallel controller | Supplied separately | GoodWe SEC3000C × 1 per system The GoodWe ETR 50-125 kW user manual (pp. 26-27) repeats the pairs for parallel systems, which require SEC3000C main program V7.8.19 or later: one SEC3000C coordinates the parallel system. | GoodWe ETR 50–125 kW – User manual |
| GoodWe GW100K-ET-G10 | Parallel controller | Supplied separately | GoodWe SEC3000C × 1 per system The SEC3000C is optional for this grid-connected LAN configuration. If you select it, check the firmware on site before commissioning. The ET manual specifies SEC main program V7.5.32 or later. The SEC manual specifies WiFi/LAN Kit-20 V2.5.49 or later. | GoodWe ET 50–100 kW – User manual (V1.2), p. 30GoodWe ET 50–100 kW – User manual (V1.2), p. 32GoodWe SEC3000C – User manual, p. 41GoodWe SEC3000C – User manual, p. 54GoodWe SEC3000C – Datasheet (EMEA), p. 1 |
| GoodWe GW100K-ET-G10 | Smart meter | Included | The ET 80 to 100 kW includes a GM330 smart meter for a single-unit system; its CTs (nA/5A, 200 to 5000 A primary) are bought separately (ET 50-100 kW manual, PDF pp. 12 and 19). | GoodWe ET 50–100 kW – System manual (V1.3) |
| GoodWe GW100K-ETR-G10 | Parallel controller | Supplied separately | GoodWe SEC3000C × 1 per system The GoodWe ETR 50-125 kW user manual (pp. 26-27) repeats the pairs for parallel systems, which require SEC3000C main program V7.8.19 or later: one SEC3000C coordinates the parallel system. | GoodWe ETR 50–125 kW – User manual |
| GoodWe GW110K-ETR-G10 | Parallel controller | Supplied separately | GoodWe SEC3000C × 1 per system The GoodWe ETR 50-125 kW user manual (pp. 26-27) repeats the pairs for parallel systems, which require SEC3000C main program V7.8.19 or later: one SEC3000C coordinates the parallel system. | GoodWe ETR 50–125 kW – User manual |
| GoodWe GW124.99K-ETR-G10 | Parallel controller | Supplied separately | GoodWe SEC3000C × 1 per system The GoodWe ETR 50-125 kW user manual (pp. 26-27) repeats the pairs for parallel systems, which require SEC3000C main program V7.8.19 or later: one SEC3000C coordinates the parallel system. | GoodWe ETR 50–125 kW – User manual |
| GoodWe GW125K-ETR-G10 | Parallel controller | Supplied separately | GoodWe SEC3000C × 1 per system The GoodWe ETR 50-125 kW user manual (pp. 26-27) repeats the pairs for parallel systems, which require SEC3000C main program V7.8.19 or later: one SEC3000C coordinates the parallel system. | GoodWe ETR 50–125 kW – User manual |
| SAJ H2-10K-T3 | Smart meter | Included | The H2 T3 includes a smart meter, three current transformers and a 10 m meter communication cable (H2 manual, section 2.2 Unpacking, PDF p. 36 English / p. 7 German). | SAJ H2 10–30K T2/T3 – User manual, p. 36 |
| SAJ H2-12K-T3 | Smart meter | Included | The H2 T3 includes a smart meter, three current transformers and a 10 m meter communication cable (H2 manual, section 2.2 Unpacking, PDF p. 36 English / p. 7 German). | SAJ H2 10–30K T2/T3 – User manual, p. 36 |
| SAJ H2-15K-T3 | Smart meter | Included | The H2 T3 includes a smart meter, three current transformers and a 10 m meter communication cable (H2 manual, section 2.2 Unpacking, PDF p. 36 English / p. 7 German). | SAJ H2 10–30K T2/T3 – User manual, p. 36 |
| SAJ H2-20K-T3 | Smart meter | Included | The H2 T3 includes a smart meter, three current transformers and a 10 m meter communication cable (H2 manual, section 2.2 Unpacking, PDF p. 36 English / p. 7 German). | SAJ H2 10–30K T2/T3 – User manual, p. 36 |
| SAJ H2-25K-T3 | Smart meter | Included | The H2 T3 includes a smart meter, three current transformers and a 10 m meter communication cable (H2 manual, section 2.2 Unpacking, PDF p. 36 English / p. 7 German). | SAJ H2 10–30K T2/T3 – User manual, p. 36 |
| SAJ H2-30K-T3-DE | Smart meter | Included | The H2 T3 includes a smart meter, three current transformers and a 10 m meter communication cable (H2 manual, section 2.2 Unpacking, PDF p. 36 English / p. 7 German). | SAJ H2 10–30K T2/T3 – User manual, p. 36 |
| SAJ HS2-5K-T2-X | Smart meter | Supplied separately | Chint DTSU666 × 1 per system SAJ's Configuration Instructions V1.0 set up the Chint DTSU666 as the three-phase meter of the H2, HS2 and HS3 systems (section 5.1, PDF pp. 32–33). | SAJ H2, HS2, HS3 – Configuration instructions (V1.0) |
| SAJ HS2-6K-T2-X | Smart meter | Supplied separately | Chint DTSU666 × 1 per system SAJ's Configuration Instructions V1.0 set up the Chint DTSU666 as the three-phase meter of the H2, HS2 and HS3 systems (section 5.1, PDF pp. 32–33). | SAJ H2, HS2, HS3 – Configuration instructions (V1.0) |
| SAJ HS2-8K-T2-X | Smart meter | Supplied separately | Chint DTSU666 × 1 per system SAJ's Configuration Instructions V1.0 set up the Chint DTSU666 as the three-phase meter of the H2, HS2 and HS3 systems (section 5.1, PDF pp. 32–33). | SAJ H2, HS2, HS3 – Configuration instructions (V1.0) |
| SAJ HS2-10K-T2-X | Smart meter | Supplied separately | Chint DTSU666 × 1 per system SAJ's Configuration Instructions V1.0 set up the Chint DTSU666 as the three-phase meter of the H2, HS2 and HS3 systems (section 5.1, PDF pp. 32–33). | SAJ H2, HS2, HS3 – Configuration instructions (V1.0) |
| SAJ HS3-5K-T2-W/G-PX | Smart meter | Included | The HS3 includes its meter, a three-phase meter from Chint, model DTSU666/iDM411 (HS3 manual V4, section 5.2.8, PDF p. 72). | SAJ HS3 3–12K-T2 – User manual (V4) |
| SAJ HS3-6K-T2-W/G-PX | Smart meter | Included | The HS3 includes its meter, a three-phase meter from Chint, model DTSU666/iDM411 (HS3 manual V4, section 5.2.8, PDF p. 72). | SAJ HS3 3–12K-T2 – User manual (V4) |
| SAJ HS3-8K-T2-W/G-PX | Smart meter | Included | The HS3 includes its meter, a three-phase meter from Chint, model DTSU666/iDM411 (HS3 manual V4, section 5.2.8, PDF p. 72). | SAJ HS3 3–12K-T2 – User manual (V4) |
| SAJ HS3-10K-T2-W/G-PX | Smart meter | Included | The HS3 includes its meter, a three-phase meter from Chint, model DTSU666/iDM411 (HS3 manual V4, section 5.2.8, PDF p. 72). | SAJ HS3 3–12K-T2 – User manual (V4) |
| SAJ HS3-12K-T2-W/G-PX | Smart meter | Included | The HS3 includes its meter, a three-phase meter from Chint, model DTSU666/iDM411 (HS3 manual V4, section 5.2.8, PDF p. 72). | SAJ HS3 3–12K-T2 – User manual (V4) |
European grid-code certificates
Documented non-released combinations
For the specific models below, the cited documents do not establish a release. Open a series to see the exact models.
GoodWe ESA Series × GoodWe BAT-C
- GoodWe GW5K-ETA-G20
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- GoodWe GW6K-ETA-G20
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- GoodWe GW8K-ETA-G20
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- GoodWe GW9.999K-ETA-G20
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- GoodWe GW10K-ETA-G20
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- GoodWe GW12K-ETA-G20
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- GoodWe GW15K-ETA-G20
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- GoodWe GW20K-ETA-G20
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- GoodWe GW25K-ETA-G20
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- GoodWe GW29.999K-ETA-G20
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- GoodWe GW30K-ETA-G20
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
GoodWe ESA Series × SAJ
- GoodWe GW5K-ETA-G20
- SAJ BC2-HV1, SAJ BU2-5.0-HV1
- GoodWe GW6K-ETA-G20
- SAJ BC2-HV1, SAJ BU2-5.0-HV1
- GoodWe GW8K-ETA-G20
- SAJ BC2-HV1, SAJ BU2-5.0-HV1
- GoodWe GW9.999K-ETA-G20
- SAJ BC2-HV1, SAJ BU2-5.0-HV1
- GoodWe GW10K-ETA-G20
- SAJ BC2-HV1, SAJ BU2-5.0-HV1
- GoodWe GW12K-ETA-G20
- SAJ BC2-HV1, SAJ BU2-5.0-HV1
- GoodWe GW15K-ETA-G20
- SAJ BC2-HV1, SAJ BU2-5.0-HV1
- GoodWe GW20K-ETA-G20
- SAJ BC2-HV1, SAJ BU2-5.0-HV1
- GoodWe GW25K-ETA-G20
- SAJ BC2-HV1, SAJ BU2-5.0-HV1
- GoodWe GW29.999K-ETA-G20
- SAJ BC2-HV1, SAJ BU2-5.0-HV1
- GoodWe GW30K-ETA-G20
- SAJ BC2-HV1, SAJ BU2-5.0-HV1
GoodWe ESA Series × SAJ BU2-HV1
- GoodWe GW5K-ETA-G20
- SAJ B2-5.0-HV1, SAJ B2-10.0-HV1, SAJ B2-15.0-HV1, SAJ B2-20.0-HV1, SAJ B2-25.0-HV1
- GoodWe GW6K-ETA-G20
- SAJ B2-5.0-HV1, SAJ B2-10.0-HV1, SAJ B2-15.0-HV1, SAJ B2-20.0-HV1, SAJ B2-25.0-HV1
- GoodWe GW8K-ETA-G20
- SAJ B2-5.0-HV1, SAJ B2-10.0-HV1, SAJ B2-15.0-HV1, SAJ B2-20.0-HV1, SAJ B2-25.0-HV1
- GoodWe GW9.999K-ETA-G20
- SAJ B2-5.0-HV1, SAJ B2-10.0-HV1, SAJ B2-15.0-HV1, SAJ B2-20.0-HV1, SAJ B2-25.0-HV1
- GoodWe GW10K-ETA-G20
- SAJ B2-5.0-HV1, SAJ B2-10.0-HV1, SAJ B2-15.0-HV1, SAJ B2-20.0-HV1, SAJ B2-25.0-HV1
- GoodWe GW12K-ETA-G20
- SAJ B2-5.0-HV1, SAJ B2-10.0-HV1, SAJ B2-15.0-HV1, SAJ B2-20.0-HV1, SAJ B2-25.0-HV1
- GoodWe GW15K-ETA-G20
- SAJ B2-5.0-HV1, SAJ B2-10.0-HV1, SAJ B2-15.0-HV1, SAJ B2-20.0-HV1, SAJ B2-25.0-HV1
- GoodWe GW20K-ETA-G20
- SAJ B2-5.0-HV1, SAJ B2-10.0-HV1, SAJ B2-15.0-HV1, SAJ B2-20.0-HV1, SAJ B2-25.0-HV1
- GoodWe GW25K-ETA-G20
- SAJ B2-5.0-HV1, SAJ B2-10.0-HV1, SAJ B2-15.0-HV1, SAJ B2-20.0-HV1, SAJ B2-25.0-HV1
- GoodWe GW29.999K-ETA-G20
- SAJ B2-5.0-HV1, SAJ B2-10.0-HV1, SAJ B2-15.0-HV1, SAJ B2-20.0-HV1, SAJ B2-25.0-HV1
- GoodWe GW30K-ETA-G20
- SAJ B2-5.0-HV1, SAJ B2-10.0-HV1, SAJ B2-15.0-HV1, SAJ B2-20.0-HV1, SAJ B2-25.0-HV1
GoodWe ET Series × GoodWe ESA Series
- GoodWe GW80K-ET-G10
- GoodWe GW5.1-BAT-D-G20, GoodWe GW5.1-BAT-D-G21, GoodWe GW6.0-BAT-D-G20, GoodWe GW8.3-BAT-D-G20, GoodWe GW8.3-BAT-D-G21, GoodWe GW9.0-BAT-D-G20
- GoodWe GW99.99K-ET-G10
- GoodWe GW5.1-BAT-D-G20, GoodWe GW5.1-BAT-D-G21, GoodWe GW6.0-BAT-D-G20, GoodWe GW8.3-BAT-D-G20, GoodWe GW8.3-BAT-D-G21, GoodWe GW9.0-BAT-D-G20
- GoodWe GW100K-ET-G10
- GoodWe GW5.1-BAT-D-G20, GoodWe GW5.1-BAT-D-G21, GoodWe GW6.0-BAT-D-G20, GoodWe GW8.3-BAT-D-G20, GoodWe GW8.3-BAT-D-G21, GoodWe GW9.0-BAT-D-G20
SAJ H2 × GoodWe BAT-C
- SAJ H2-10K-T3
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- SAJ H2-12K-T3
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
SAJ H2 × SAJ BU2-HV1
- SAJ H2-10K-T3
- SAJ B2-5.0-HV1
- SAJ H2-12K-T3
- SAJ B2-5.0-HV1
SAJ HS2 × GoodWe BAT-C
- SAJ HS2-5K-T2-X
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- SAJ HS2-6K-T2-X
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- SAJ HS2-8K-T2-X
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- SAJ HS2-10K-T2-X
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
SAJ HS2 × GoodWe ESA Series
- SAJ HS2-5K-T2-X
- GoodWe GW5.1-BAT-D-G20, GoodWe GW5.1-BAT-D-G21, GoodWe GW6.0-BAT-D-G20, GoodWe GW8.3-BAT-D-G20, GoodWe GW8.3-BAT-D-G21, GoodWe GW9.0-BAT-D-G20
- SAJ HS2-6K-T2-X
- GoodWe GW5.1-BAT-D-G20, GoodWe GW5.1-BAT-D-G21, GoodWe GW6.0-BAT-D-G20, GoodWe GW8.3-BAT-D-G20, GoodWe GW8.3-BAT-D-G21, GoodWe GW9.0-BAT-D-G20
- SAJ HS2-8K-T2-X
- GoodWe GW5.1-BAT-D-G20, GoodWe GW5.1-BAT-D-G21, GoodWe GW6.0-BAT-D-G20, GoodWe GW8.3-BAT-D-G20, GoodWe GW8.3-BAT-D-G21, GoodWe GW9.0-BAT-D-G20
- SAJ HS2-10K-T2-X
- GoodWe GW5.1-BAT-D-G20, GoodWe GW5.1-BAT-D-G21, GoodWe GW6.0-BAT-D-G20, GoodWe GW8.3-BAT-D-G20, GoodWe GW8.3-BAT-D-G21, GoodWe GW9.0-BAT-D-G20
SAJ HS3 × GoodWe BAT-C
- SAJ HS3-6K-T2-W/G-PX
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- SAJ HS3-8K-T2-W/G-PX
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- SAJ HS3-12K-T2-W/G-PX
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
SAJ HS3 × GoodWe ESA Series
- SAJ HS3-6K-T2-W/G-PX
- GoodWe GW5.1-BAT-D-G20, GoodWe GW5.1-BAT-D-G21, GoodWe GW6.0-BAT-D-G20, GoodWe GW8.3-BAT-D-G20, GoodWe GW8.3-BAT-D-G21, GoodWe GW9.0-BAT-D-G20
- SAJ HS3-8K-T2-W/G-PX
- GoodWe GW5.1-BAT-D-G20, GoodWe GW5.1-BAT-D-G21, GoodWe GW6.0-BAT-D-G20, GoodWe GW8.3-BAT-D-G20, GoodWe GW8.3-BAT-D-G21, GoodWe GW9.0-BAT-D-G20
- SAJ HS3-12K-T2-W/G-PX
- GoodWe GW5.1-BAT-D-G20, GoodWe GW5.1-BAT-D-G21, GoodWe GW6.0-BAT-D-G20, GoodWe GW8.3-BAT-D-G20, GoodWe GW8.3-BAT-D-G21, GoodWe GW9.0-BAT-D-G20
SAJ × GoodWe BAT-C
- SAJ H2-15K-T3
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- SAJ H2-20K-T3
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- SAJ H2-25K-T3
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- SAJ H2-30K-T3-DE
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- SAJ HS3-5K-T2-W/G-PX
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
- SAJ HS3-10K-T2-W/G-PX
- GoodWe GW61.4-BAT-AC-G10, GoodWe GW112.6-BAT-AC-G10
SAJ × GoodWe ESA Series
- SAJ HS3-5K-T2-W/G-PX
- GoodWe GW5.1-BAT-D-G20, GoodWe GW5.1-BAT-D-G21, GoodWe GW6.0-BAT-D-G20, GoodWe GW8.3-BAT-D-G20, GoodWe GW8.3-BAT-D-G21, GoodWe GW9.0-BAT-D-G20
- SAJ HS3-10K-T2-W/G-PX
- GoodWe GW5.1-BAT-D-G20, GoodWe GW5.1-BAT-D-G21, GoodWe GW6.0-BAT-D-G20, GoodWe GW8.3-BAT-D-G20, GoodWe GW8.3-BAT-D-G21, GoodWe GW9.0-BAT-D-G20
SAJ × SAJ BU2-HV1
- SAJ H2-15K-T3
- SAJ B2-5.0-HV1
- SAJ H2-20K-T3
- SAJ B2-5.0-HV1
- SAJ H2-25K-T3
- SAJ B2-5.0-HV1
- SAJ H2-30K-T3-DE
- SAJ B2-5.0-HV1
Planning & Commissioning Guides
- System DesignInverter and Battery Pairing Checklist: 4 Pre-Installation Checks for Voltage, BMS, Firmware, and Metering
- System DesignHybrid Inverter vs. AC-Coupled Storage: A 4-Step Selection Guide for New Solar Builds and Retrofits
- Installation & CommissioningCommissioning solar and storage
- ApplicationsC&I Battery Storage Planning: How to Size Peak Shaving, Backup Reserves, and Multi-Unit Scalability Without Conflicting Goals