Description
Symmetrical 4-tracker routing for complex commercial roofs.
GoodWe GW50K-ET-10 is a 50 kW flagship commercial three-phase hybrid inverter with 4 independent 42 A MPPT trackers and a 100 A storage interface, delivering 75,000 W solar intake and 75 kVA surge capability to start heavy industrial machinery without tripping.
4 Independent 42 A MPPT Trackers
Symmetrical high-current design across all 4 channels accommodates 8 strings of 182/210 mm bifacial panels.
75 kVA Inductive Motor Starting Surge
Delivers 150% apparent surge power (10s) to effortlessly ride through heavy compressor startup inrush.
100 A Heavy Commercial Battery Port
Pushes up to 50 kW continuous DC power directly into large C&I battery storage containers.
Consolidated Single-Chassis Installation
Replaces multiple 25 kW units, cutting redundant AC breakers, combiner boxes, and installation labor.
More product details
Sprawling logistics warehouses and commercial facilities with 4 distinct roof aspects suffer heavy mismatch losses if grouped on fewer trackers. The GW50K-ET-10 provides 4 independent 42 A MPPT trackers (Isc 55 A), optimizing 8 strings of 600W+ bifacial modules without thermal current throttling.
- 4 symmetrical MPPT channels allow dedicated tracking for East, South, West, and carport pitches with zero cross-string clipping.
- Absorbs up to 75,000 W of solar generation, routing power directly into industrial loads and 100 A storage racks.
- Wide MPPT window (200–850 V) delivers 98.1% peak conversion efficiency under full continuous load.

GoodWe
Compare different models
Scroll sideways to compare every model.

Heavy commercial battery throughput with 75 kVA motor starting capacity.
Transitioning into heavy commercial storage, the GW50K-ET-10 delivers 100 A continuous DC throughput across a wide 200–800 V window, while supplying 75,000 VA peak apparent surge power for 10 seconds. Pushes up to 50 kW continuous DC charge and discharge into commercial storage containers (such as GoodWe Lynx C). 75 kVA apparent power surge tolerance (10 seconds) effortlessly rides through locked-rotor inrush currents on heavy compressors. IP66 heavy-duty cast-aluminum casing provides complete dust and high-pressure water protection (-35 to +60 °C).
Fits 42 A and 32 A across four MPPTs
Four MPPT inputs take 42 A, 32 A, 42 A, and 32 A max currents. Two dedicated strings attach to each tracker with short-circuit current ratings up to 55 A.
Pairs 200 to 800 V commercial storage
A single high-voltage port interfaces with 200 to 800 V Li-Ion battery banks. CAN communication coordinates continuous charge and discharge cycling with the BMS.
Stands up to extreme outdoor climates
Smart fan cooling stabilizes internal temperatures from minus 35 to plus 60 C. The 520 x 660 x 260 mm enclosure is fully IP66 rated for outdoor walls.
Technical data
The flagship 50 kW commercial hybrid engine engineered for heavy industrial electrification.
4 MPPTs with 75 kWp solar intake and 75 kVA inductive starting surge.
Rather than deploying multiple smaller inverters with separate battery ports, a single GW50K-ET-10 delivers 50 kW continuous AC throughput (75.8 A). Its 4 independent 42 A MPPT trackers accommodate modern 600W+ bifacial panels across 8 strings, while the 100 A battery interface pushes up to 50 kW directly into commercial battery racks (such as GoodWe Lynx C) for aggressive peak shaving.
- Continuous 3-Phase Power
- 50,000 VA
- 150% Solar DC Intake
- 75,000 Wp
- Direct High-Voltage Storage Port
- 100 A
- 10-Second Starting Surge
- 75 kVA
Power & Phase
- Phase
- 3
- Nominal output power (W)
- 50 kW
- Max. apparent power to / from grid (VA)
- 50 kVA
- Power factor
- ~1 (adjustable 0.8 leading to 0.8 lagging)
- Back-up nominal apparent power (VA)
- 50 kVA
PV Input
- Max. input power (W)
- 75 kW
- Max. input voltage (V)
- 1000
- MPPT operating voltage range (V)
- 165 ~ 850
- Nominal input voltage (V)
- 620
- Max. input current per MPPT (A)
- 42 / 32 / 42 / 32
- Max. short circuit current per MPPT (A)
- 55 / 42 / 55 / 42
- Number of strings per MPPT
- 2
- MPPT efficiency
- 99.0%
Battery Interface
- Battery voltage class
- HV
- Battery type
- Li-Ion
- Nominal battery voltage (V)
- 500
- Battery voltage range (V)
- 200 ~ 800
- Number of battery inputs
- 1
Efficiency & Protection
- Max. efficiency
- 98.1%
- European efficiency
- 97.5%
- Max. battery to AC efficiency
- 97.7%
- MPPT efficiency
- 99.0%
- Ingress protection rating
- IP66
- Cooling method
- Smart fan cooling
Physical & Comms
- Dimension (W x H x D mm)
- 520 x 660 x 260
- Weight (kg)
- 65
- Operating temperature range (C)
- -35 ~ +60
- Communication with BMS
- CAN
Project fit
Where this model fits.
Scenarios that show which projects the GoodWe GW50K-ET-10 belongs in, what to verify before quoting, and when another model is the better pick.
Multi-Pitch Logistics Warehouses & Industrial Carports (60–75 kWp PV)

Sprawling commercial roofs with 4 distinct pitches or layouts (East, South, West, and carport canopy) requiring dedicated string optimization.
The 4 independent 42 A MPPTs allow dedicated tracking for each orientation while accepting high-current bifacial modules, capturing maximum solar power without DC optimizers.
- BoundaryIf total solar capacity is under 60 kWp and roof layout requires only 3 MPPT channels, step down to the 40 kW model to save equipment cost.
- If total solar capacity is under 60 kWp and roof layout requires only 3 MPPT channels, step down to the 40 kW model to save equipment cost.
Heavy Commercial Workshops with Large Inductive Motor Starting Loads

Industrial workshops operating large hydraulic pumps, three-phase compressors, or wood/metalworking machinery requiring heavy surge current.
The 75 kVA (10s) surge headroom ensures reliable operation during peak motor startup spikes, while the 100 A battery port delivers 50 kW continuous power to shave daytime peak tariff charges.
- Confirm this model against the adjacent rating in the same family
Documents
GoodWe ET50 Series 40-50 kW datasheet (EMEA, EN)Product questions
Why choose a single 50 kW hybrid inverter over two 25 kW units?
Eliminates redundant switchgear, saves pad space, and simplifies EMS communication. A single GW50K-ET-10 significantly simplifies commercial installations: it eliminates redundant AC distribution breakers and combiner panels, requires only a single smart meter communication loop (RS485), and needs only one 100 A battery connection to drive large battery banks (such as GoodWe Lynx C). It also takes up less equipment pad space while delivering higher round-trip efficiency.
Is an external Static Transfer Switch (STS) required for automatic backup operation?
Yes. The GoodWe GW125K-STS-G10 is required for automatic whole-facility transfer. For automatic whole-facility transfer between on-grid and off-grid modes across the facility distribution panel, the external GoodWe GW125K-STS-G10 switch is required to provide utility-grade motorized isolation.
What is the maximum continuous AC export current on this model?
75.8 A max output current; 100 A or 125 A 3-pole industrial MCCB. * Nominal Output Current: Approx. 72.5 A per phase at 400 V three-phase. * Maximum Output Current: 75.8 A per phase (50,000 VA continuous apparent power limit). * Breaker Recommendation: A 3-pole 100 A or 125 A industrial circuit breaker (MCCB) on the main AC distribution board.
Can this model be paired with multiple battery racks in parallel?
Yes. Direct connection to commercial high-voltage racks up to 156 kWh. When paired with GoodWe Lynx C commercial storage, you can connect battery racks from 101 kWh up to 156 kWh to the 100 A port, delivering full 50 kW continuous charge and discharge for dynamic peak shaving and energy arbitrage.
System components
Required components
GoodWe GM3000 three-phase meter
Item number: DLK-GOODWE-GM3000
Dedicated three-phase direct meter sized for C&I export control on this power tier.
Recommended components
GoodWe LX C138-10 / LX C156-10 battery cabinet
Item number: DLK-GOODWE-LXC13810
Listed by GoodWe against the ET 40-50 kW range at full inverter power; LX C101-10 and LX C120-10 are also listed but cannot reach the inverter's full rated output.
GoodWe GW112.6-BAT-AC-G10 battery cabinet
Item number: DLK-GOODWE-GW1126BATACG10
Listed by GoodWe against the ET 40-50 kW range at full power (ARM 10+); the smaller GW61.4-BAT-AC-G10 is also listed but is capped below full inverter output on this tier.
Optional components
GoodWe SEC3000C
Item number: DLK-GOODWE-SEC3000C
Parallel connection of GoodWe on-grid and hybrid inverters with a built-in meter, removing the need for a separate meter or 4G router on a C&I site.
Approved pairings
GoodWe GW112.6-BAT-AC-G10Item number DLK-GOODWE-GW1126BATACG10GoodWe requires ARM 10 or higher, and prints: 'The BAT series GW61.4-BAT-AC-G10 model paired with ET (40-50kW) cannot achieve full power output from the inverter.'
GoodWe GW61.4-BAT-AC-G10Item number DLK-GOODWE-GW614BATACG10GoodWe requires ARM 10 or higher, and prints: 'The BAT series GW61.4-BAT-AC-G10 model paired with ET (40-50kW) cannot achieve full power output from the inverter.'
GoodWe GW60KWH-D-10Item number DLK-GOODWE-GW60KWHD10GoodWe prints, verbatim: 'ET 50kW with Lynx C-Series LX C101-10, LX C120-10 cannot reach the maximum power of the inverter.' GW60KWH-D-10 is not listed here; it is listed against the ET 15-30.
GoodWe LX C101-10Item number DLK-GOODWE-LXC10110GoodWe prints, verbatim: 'ET 50kW with Lynx C-Series LX C101-10, LX C120-10 cannot reach the maximum power of the inverter.' GW60KWH-D-10 is not listed here; it is listed against the ET 15-30.
GoodWe LX C120-10Item number DLK-GOODWE-LXC12010GoodWe prints, verbatim: 'ET 50kW with Lynx C-Series LX C101-10, LX C120-10 cannot reach the maximum power of the inverter.' GW60KWH-D-10 is not listed here; it is listed against the ET 15-30.
GoodWe LX C138-10Item number DLK-GOODWE-LXC13810GoodWe prints, verbatim: 'ET 50kW with Lynx C-Series LX C101-10, LX C120-10 cannot reach the maximum power of the inverter.' GW60KWH-D-10 is not listed here; it is listed against the ET 15-30.
GoodWe LX C156-10Item number DLK-GOODWE-LXC15610GoodWe prints, verbatim: 'ET 50kW with Lynx C-Series LX C101-10, LX C120-10 cannot reach the maximum power of the inverter.' GW60KWH-D-10 is not listed here; it is listed against the ET 15-30.
Pylontech FH10050Item number DLK-PYLONTECH-FH10050Pylontech Ver. 2.43 lists a Force-H3 stack of 3 to 7 modules. Our Force-H3 10.24 kWh is 2 modules and is below the minimum.
Pylontech Force-H3 10.24 kWh (2 x FH10050)Item number DLK-PYLONTECH-FORCEH31024KWHPylontech Ver. 2.43 lists a Force-H3 stack of 3 to 7 modules. Our Force-H3 10.24 kWh is 2 modules and is below the minimum.
Pylontech Force-H3 15.36 kWh (3 x FH10050)Item number DLK-PYLONTECH-FORCEH31536KWHPylontech Ver. 2.43 lists a Force-H3 stack of 3 to 7 modules. Our Force-H3 10.24 kWh is 2 modules and is below the minimum.
Pylontech Force-H3 20.48 kWh (4 x FH10050)Item number DLK-PYLONTECH-FORCEH32048KWHPylontech Ver. 2.43 lists a Force-H3 stack of 3 to 7 modules. Our Force-H3 10.24 kWh is 2 modules and is below the minimum.
Pylontech Force-H3 25.6 kWh (5 x FH10050)Item number DLK-PYLONTECH-FORCEH3256KWHPylontech Ver. 2.43 lists a Force-H3 stack of 3 to 7 modules. Our Force-H3 10.24 kWh is 2 modules and is below the minimum.
Pylontech Force-H3 30.72 kWh (6 x FH10050)Item number DLK-PYLONTECH-FORCEH33072KWHPylontech Ver. 2.43 lists a Force-H3 stack of 3 to 7 modules. Our Force-H3 10.24 kWh is 2 modules and is below the minimum.
Pylontech Force-H3 35.84 kWh (7 x FH10050)Item number DLK-PYLONTECH-FORCEH33584KWHPylontech Ver. 2.43 lists a Force-H3 stack of 3 to 7 modules. Our Force-H3 10.24 kWh is 2 modules and is below the minimum.