- Accuracy class
- Class B / 1.0
- Communication
- Modbus-RTU
- Ingress protection
- IP20
- Communication address range
- 1~247
In stock
In stock
Chint DTSU666 is the standard grid-point telemetry meter for SAJ HS2-5K to 10K-T2-X (added separately) and is included pre-bundled on SAJ HS3-5K to 12K-T2 systems (DTSU666/iDM411). Always confirm RS485 address and baud rate in the inverter commissioning manual.
No. Even though the manufacturer brochure cites MID B+D and EN 50470-1/-3, standalone MID certificates are not hosted on de-linker.com and grid billing in Germany is legally performed solely by the metering point operator's (Messstellenbetreiber) official revenue meter.
DTSU666 measures three-phase four-wire networks (3×220/380 V to 3×240/415 V, 0.8–1.15 Un) at 0.25–5(80) A with ≤ 2 W / 10 VA power draw, operating from −25 to +55 °C inside an IP20 distribution enclosure.
When deploying GoodWe commercial ET-10, ET-G10, or ETR-G10 inverters or distribution feeders exceeding 80 A direct connection, specify GoodWe GM330 with site-matched nA:5 A current transformers (or GoodWe GMK330 up to 120 A).