Search the site

HOME / PRODUCTS / CHINT
THREE-PHASE SYSTEM TELEMETRY METER · 1 ACTIVE SKU

Chint

Equip three-phase hybrid storage installations with the Chint DTSU666 DIN-rail smart energy meter—a compact 4-module (72 × 100 × 65 mm, ~0.33 kg) four-wire (3P4W) instrument engineered for grid-point import/export telemetry, zero-export control, and Solarspitzengesetz active-power capping. Operating across 3 × 220/380 V to 3 × 240/415 V (0.8 Un to 1.15 Un) with 0.25–5(80) A current measurement, −25 to +55 °C rated temperature range, IP20 panel housing, and ≤ 2 W / 10 VA self-consumption, DTSU666 communicates reliably over RS485 Modbus (addresses 1–247) with SAJ HS2, HS3, and compatible three-phase hybrid inverters.

It classifies cleanly under EU CN 2026 code 9028 30 19 as non-dangerous goods. While the manufacturer brochure references MID B+D and EN 50470-1/-3, standalone MID certificates are not hosted on site and the meter serves system control exclusively—never replacing the grid operator's revenue billing meter.

Key technical span

0.25–5(80) A 3-phase input
3P4W · 80 A
Addresses 1–247 telemetry
RS485 Modbus
DIN-rail IP20 (~0.33 kg)
72 × 100 × 65 mm
Non-ADR polyphase meter
CN 9028 30 19

1-1 / 1 product family

Planning & Commissioning Guides

Chint

Buyer Q&A

Which inverters in the Linker portfolio pair directly with Chint DTSU666?

Chint DTSU666 is the standard grid-point telemetry meter for SAJ HS2-5K to 10K-T2-X (added separately) and is included pre-bundled on SAJ HS3-5K to 12K-T2 systems (DTSU666/iDM411). Always confirm RS485 address and baud rate in the inverter commissioning manual.

Does Chint DTSU666 replace the utility's official bidirectional billing meter in Germany?

No. Even though the manufacturer brochure cites MID B+D and EN 50470-1/-3, standalone MID certificates are not hosted on de-linker.com and grid billing in Germany is legally performed solely by the metering point operator's (Messstellenbetreiber) official revenue meter.

What are the electrical limits and self-consumption of Chint DTSU666?

DTSU666 measures three-phase four-wire networks (3×220/380 V to 3×240/415 V, 0.8–1.15 Un) at 0.25–5(80) A with ≤ 2 W / 10 VA power draw, operating from −25 to +55 °C inside an IP20 distribution enclosure.

When should a commercial site switch from DTSU666 to GoodWe GM330 with external CTs?

When deploying GoodWe commercial ET-10, ET-G10, or ETR-G10 inverters or distribution feeders exceeding 80 A direct connection, specify GoodWe GM330 with site-matched nA:5 A current transformers (or GoodWe GMK330 up to 120 A).

CONTACT LINKER

Not sure which model to look for?

Your question includes this page as context. You can remove it before sending.