Description
SAJ H2-12K-T3 is a three-phase hybrid inverter with 12,000 W rated AC power and 13,200 VA maximum apparent power. It has three MPPTs for up to 24,000 Wp of PV, two battery inputs for 180–800 V LiFePO4 batteries and a backup output.
- Rated AC output
- 12 kW
- Max PV input
- 24 kWp
- MPPT
- 3
- Battery voltage
- 180–800 V
- Phases
- 3
SAJ H2-12K-T3 (12 kW three-phase hybrid inverter)
PV array power up to 24,000 Wp (STC) on three MPPTs with two strings each.
40 A maximum DC input current and 50 A maximum short-circuit current per MPPT.
Backup output with 12,000 VA and a peak of 18,000 VA for 3 s.
Supplied with the eSolar AIO3 communication module, a smart meter and three current transformers.
Three MPPTs with 40 A each.
Each of the three MPPTs takes two strings, with 40 A maximum DC input current and 50 A maximum short-circuit current per MPPT. The MPPT voltage range is 180–900 V, the maximum DC voltage 1000 V and the start voltage 180 V.
Backup output with a switch-over time of ≤ 20 ms.
The backup output supplies up to 12,000 VA and a peak apparent power of 18,000 VA for 3 s; the switch-over time to backup is ≤ 20 ms. The backup function needs a properly grounded backup PE line and earthing bar.

SAJ H2
Two battery inputs for 180–800 V.
The inverter has two battery inputs (BAT1 and BAT2) for LiFePO4 batteries with a battery voltage range of 180–800 V and a maximum charge and discharge current of 50 A. The SAJ B2 high-voltage battery is used as a set with the H2; the B2's own maximum charge and discharge current is 30 A.
Technical data
Main figures of the H2-12K-T3
- Rated AC power
- 12,000 W
- Max. PV array power
- 24,000 Wp
- Max. battery charge / discharge current
- 50 A
- Max. DC input current
- 40 A / MPPT
About these specifications
12,000 W rated AC power, 24,000 Wp PV, three MPPTs.
PV input
- Max. PV array power
- 24000 Wpat STC
- Max. DC voltage
- 1000 V
- MPPT voltage range
- 180–900 V
- Rated DC voltage
- 600 V
- Start voltage
- 180 V
- Max. DC input current per MPPT
- 40 / 40 / 40 A
- Max. DC short-circuit current per MPPT
- 50 / 50 / 50 A
- Number of MPPTs
- 3
- Strings per MPPT
- 2 / 2 / 2
Battery connection
- Battery type
- LiFePO4
- Battery voltage range
- 180–800 V
- Max. charge / discharge current
- 50 A
- Number of battery inputs
- 2
AC output (on-grid)
- Rated AC power
- 12000 W
- Max. apparent power
- 13200 VA
- Rated output current
- 17.4 Aat 230 V AC
- Max. output current
- 19.2 A
- Rated AC voltage
- 3L+N+PE, 220/380, 230/400, 240/415 V
- AC voltage range
- 180–280 / 312–485 V
- Rated output frequency / range
- 50, 60 / 45–55, 55–65 Hz
- Power factor (cos φ)
- 0.8 leading to 0.8 lagging
- Total harmonic distortion (THDi)
- < 3 %
AC input (on-grid)
- Rated AC voltage
- 3L+N+PE, 220/380, 230/400, 240/415 V
- AC voltage range
- 180–280 / 312–485 V
- Rated input frequency
- 50, 60 Hz
- Max. input current
- 28.3 Aat 230 V AC
AC output (backup)
- Max. output power
- 12000 VA
- Max. output current
- 17.4 A
- Peak output apparent power
- 18000 VAfor 3 s
- Rated AC voltage
- 3L+N+PE, 220/380, 230/400, 240/415 V
- AC voltage range
- 180–280 / 312–485 V
- Rated output frequency / range
- 50, 60 / 45–55, 55–65 Hz
- Output voltage distortion (THDv)
- < 3 %at linear load
- Backup switch-over time
- ≤ 20 ms
Efficiency
- Max. efficiency
- 98.0 %
- European efficiency
- 97.6 %
Protection
- Battery input reverse-polarity protection
- Integrated
- Overload protection
- Integrated
- AC short-circuit current protection
- Integrated
- DC surge protection
- Type II
- AC surge protection
- Type II
- Anti-islanding protection
- Integrated
- AFCI protection
- Integrated
Interfaces
- AC connection
- Terminal block
- Display
- LED and app
- Communication
- Wi-Fi / Ethernet / 4G (optional)
General data
- Topology
- Non-isolated
- Operating temperature range
- -40 to +60 °Cderating at 45 °C and above
- Cooling
- Intelligent fan cooling
- Ambient humidity
- 0–100 %non-condensing
- Altitude
- 4000 mpower derating above 3000 m
- Noise
- < 50 dB(A)
- Ingress protection
- IP65
- Dimensions (H × W × D)
- 576 × 659 × 242 mm
- Weight
- 50 kg
- Warranty (years)
- 10
- Standards
- EN 62109-1/2, EN 61000-6-2/4, EN 50438, EN 50549, C10/11, IEC 62116, IEC 61727, RD 1699, RD 413, UNE 206006, UNE 206007, NTS, CEI 0-16, CEI 0-21, AS 4777.2, NBR 16149, NBR 16150, VDE-AR-N 4105, VDE 0126-1-1
Documents

Product questions
What does the H2-12K-T3 package contain?
The package contains: H2 inverter x1, hexagon Philips bolt group M5x12 screw x5, PV connectors T3*6 x2 and T2*4 x2, pluggable terminal blocks (2-pin x2, 3-pin x1, 6-pin x1), waterproof communication terminal cover x1, mounting bracket x1, positive battery connector x2, negative battery connector x2, AC terminal x10, M6x50 screw suite x4, eSolar AIO3 x1, waterproof AC terminal cover x1, smart meter x1, current transformer x3, meter COMM cable x1 (10 m), documents, RJ45 plug x10, and correct transformer CTF16-2K5-100. The documents include the user manual, quick installation guide, warranty card and packaging list.
Which circuit breaker and AC cable does the H2-12K-T3 need?
For the H2-12K-T3, the recommended breaker specification is 50 A. Do not connect multiple inverters to one AC circuit breaker. The AC cable cross-sectional area range is 10 to 16 mm², with 16 mm² recommended. The additional grounding cable cross-sectional area is 8 mm².
Which battery connection does the H2-12K-T3 have?
The H2-12K-T3 has a quick connector for the battery connection.
Compatibility records
| Compatible model | Category | Rating | Status & required accessory |
|---|---|---|---|
| SAJ B2-10.0-HV1Item number DLK-SAJ-B2100HV1 | Home Storage | 10 kWh | Released with accessorySAJ BC2-HV1 [1] [2] [3] [4] |
| SAJ B2-15.0-HV1Item number DLK-SAJ-B2150HV1 | Home Storage | 15 kWh | Released with accessorySAJ BC2-HV1 [1] [2] |
| SAJ B2-20.0-HV1Item number DLK-SAJ-B2200HV1 | Home Storage | 20 kWh | Released with accessorySAJ BC2-HV1 [1] [2] |
| SAJ B2-25.0-HV1Item number DLK-SAJ-B2250HV1 | Home Storage | 25 kWh | Released with accessorySAJ BC2-HV1 [1] [2] |
| SAJ BC2-HV1Item number DLK-SAJ-BC2HV1 | Home Storage | Released with accessorySAJ BC2-HV1 [1] [2] | |
| SAJ BU2-5.0-HV1Item number DLK-SAJ-BU250HV1 | Home Storage | 5 kWh | Released with accessorySAJ BC2-HV1 [1] [2] [5] [6] |
- SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and the B2 manual (V1.2, PDF p5) says the B2 can only be used as such a set: the control module is a separate product.
- SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range.
- SAJ's B2 datasheet gives 179.2 to 230.4 V for the two-module B2-10.0; the H2 T3 manual's battery voltage range begins at 180 V.
- SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. SAJ's B2 datasheet gives 179.2 to 230.4 V for the two-module B2-10.0; the H2 T3 manual's battery voltage range begins at 180 V.
- One BU2-5.0 module alone operates at 89.6 to 115.2 V (SAJ's B2 datasheet gives this for the one-module B2-5.0), below the H2 T3's battery voltage range of 180 to 800 V; two modules operate at 179.2 to 230.4 V.
- SAJ's Configuration Instructions V1.0 (Section 2) give the H2 series system as H2 + BC2 + BU2. SAJ's B2 datasheet names B2-5.0 to B2-25.0 as one to five BU2-5.0 modules with one BC2-HV1 control module, and SAJ's B2 manual (V1.2, PDF p5) says the B2 can only be used as a set with SAJ's H2 high voltage series storage inverter. The listing does not cover the one-module B2-5.0, whose operating voltage lies below the H2 T3's battery voltage range. One BU2-5.0 module alone operates at 89.6 to 115.2 V (SAJ's B2 datasheet gives this for the one-module B2-5.0), below the H2 T3's battery voltage range of 180 to 800 V; two modules operate at 179.2 to 230.4 V.
Compare models in this series
| Model | Rated AC output | Max PV input | Phases | MPPT | Battery voltage | Pairings in the matrix | AC limit |
|---|---|---|---|---|---|---|---|
| H2-10K-T3 | 10 kW | 20 kWp | 3 | 3 | 180–800 V | 6 | — |
| H2-12K-T3 | 12 kW | 24 kWp | 3 | 3 | 180–800 V | 6 | — |
| H2-15K-T3 | 15 kW | 30 kWp | 3 | 3 | 180–800 V | 6 | — |
| H2-20K-T3 | 20 kW | 40 kWp | 3 | 3 | 180–800 V | 6 | — |
| H2-25K-T3 | 25 kW | 45 kWp | 3 | 3 | 180–800 V | 6 | 27.5 kVA maximum |
| H2-30K-T3-DE | 29.999 kW | 45 kWp | 3 | 3 | 180–800 V | 6 | 29.999 kVA maximum |
Planning & Commissioning Guides
- System DesignHybrid Inverter vs. AC-Coupled Storage: A 4-Step Selection Guide for New Solar Builds and Retrofits
- Battery StorageEcoFlow, GoodWe, SAJ, and Pylontech: Four Diverging Storage Routes Reshaping Europe’s Solar Ecosystem (2026)
- Battery StorageHow to Size Battery Storage for Residential Backup: A 4-Step Guide to Critical Loads, Surge Power, Usable kWh, and Transfer Switches