The GW124.99K-ETR-G10 is rated 124.99 kW AC with 250 kW maximum PV input on 10 MPPTs. Backup requires an STS Box or STS Cabinet.
- AC limit
- 124.99 kVA maximum
- Rated AC output
- 124.99 kW
- Max PV input
- 250 kWp
- MPPT
- 10
- Battery voltage
- 700 – 1000 V
Model comparison
Grid-Threshold Selection Note
For a German medium-voltage connection, assess the 135 kW boundary using active power, including existing generation at the connection. The certification route under VDE-AR-N 4110 and NELEV also depends on total installed capacity and agreed export power.
| Datasheet rating | Current modelGW124.99K-ETR-G10 | GW125K-ETR-G10 |
|---|---|---|
| Maximum apparent power to grid | 124.99 kVA | 137.5 kVA |
| Maximum grid current at 400 V | 180.5 A | 198.5 A |
| Maximum charge and discharge power | 124.99 kW | 137.5 kW |
| Maximum on-grid active power | 124.99 kW | 137.5 kW |
GoodWe GW124.99K-ETR-G10 (124.99 kW three-phase hybrid inverter)
124.99 kW continuous output (124.99 kW max) on 3L/N/PE.
250 kW PV on 10 MPPTs, 2 strings per tracker, 42 A / 55 A.
One 700–1000 V LFP port at 178.5 A / 124.99 kW; pairing with GW261.2-BAT-LCD-G10, Voc > 813 V.
Backup path needs an STS Box or STS Cabinet; switchover <10 ms on one unit.
Takes 124.99 kW on a 700 to 1000 V battery bus
The battery port operates from 700 to 1000 V with a 750 V nominal rating and 700 V start-up. Continuous charge and discharge current reaches 178.5 A. The Battery Compatibility Overview names GW261.2-BAT-LCD-G10 for ETR 80–125 kW; PV string Voc must sit above 813 V with that cabinet.
Fits 250 kW across 10 MPPT channels
10 MPPT trackers handle 42 A each with 2 strings per tracker. Operating voltage spans 160 to 1000 V with a 1100 V maximum input rating. Between 1000 V and 1100 V the inverter stands by and returns to work at 1000 V.
Holds 124.99 kVA backup with an external STS
With an STS Box or STS Cabinet, one unit supplies 124.99 kVA of backup apparent power. Off-grid peak ratings are 120% for 60 s and 150% for 10 s. Transfer takes less than 10 ms on a single unit.
IP66 wall unit, 98 kg
The wall-mounted unit measures 995 × 758 × 358 mm and weighs 98 kg. Intelligent air cooling, 60 dB noise emission and −35 to +60 °C operation. Remote shutdown is integrated.
Technical data
AC Output (On-Grid)
- Rated / max. power
- 124.99 kW rated / 124.99 kW max (GW124.99K-ETR-G10)
- Rated / max. apparent power
- 124.99 kVA / 124.99 kVA
- Rated / max. current at 400 V
- 180.5 A / 180.5 A
- Nominal voltage
- 220/380, 230/400, 240/415 V, 3L/N/PE, 50/60 Hz
- Power factor / THDi
- ~1, adjustable 0.8 leading – 0.8 lagging / THDi <3%
- Maximum grid current at 380 V
- 190.0 A
- Maximum grid current at 415 V
- 174.0 A
PV Input
- Max. PV input power
- 250 kW maximum PV input (GW124.99K-ETR-G10)
- Max. input voltage
- 1100 V (standby above 1000 V)
- MPPT operating voltage range
- 160–1000 V; start-up 200 V; nominal 620 V
- MPPTs / strings
- 10 MPPTs, 2 strings per MPPT
- Max. MPPT current / short-circuit current
- 42 A / 55 A per MPPT
Battery Interface
- Battery type / voltage window
- LFP; 700–1000 V, nominal 750 V, start-up 700 V, one battery connection port
- Max. charge / discharge power
- 124.99 kW
- Max. continuous charge / discharge current
- 178.5 A
- Compatible battery system
- ETR 80–125 kW: GW261.2-BAT-LCD-G10; PV string Voc must exceed 813 V with that cabinet.
Backup (with STS)
- Nominal / max. backup apparent power
- 124.99 kVA / 124.99 kVA; STS Box or STS Cabinet required
- Peak output power without grid
- 120% for 60 s, 150% for 10 s
- On/off-grid switching time
- <10 ms (one unit)
Efficiency & General
- Max. / European efficiency
- 98.1% / 97.7%
- Max. battery-to-AC efficiency
- 98.2%
- Enclosure / environment
- IP66, -35 to +60 °C, 0–100% RH, max. 4,000 m, intelligent air cooling, noise 60 dB
- Dimensions / weight / mounting
- 995 × 758 × 358 mm / 98 kg / wall-mounted
- Communication
- RS485, Wi-Fi, LAN, Bluetooth, 4G; Modbus TCP (SunSpec compatible); CAN to BMS; LED + optional LCD + app
- Inverter package
- Includes GM330 meter × 1, smart dongle × 1, 10 m meter cable, 5 m parallel cable, PV and battery connectors
- MPPT efficiency
- 99.9%
- Grid documents on this page
- VDE-AR-N 4105, EN 50549-1, EN 50549-2, IEC 61727 / IEC 62116, EU Declaration of Conformity
Project fit
Where this model fits.
Scenarios that show which projects the GoodWe GW124.99K-ETR-G10 (124.99 kW three-phase hybrid inverter) belongs in, and the limits behind our engineers' recommendation.
Working within an existing grid connection
A business adding battery storage to an existing connection needs three separate figures for the grid application: active power, apparent power and line current. On the GW124.99K-ETR-G10 the rated and maximum grid outputs coincide. They are 124.99 kW of active power and 124.99 kVA of apparent power.
At 400 V the maximum line current is 180.5 A. The GW125K-ETR-G10 has the same rated current, but its maximum reaches 198.5 A. That higher figure changes the design of the AC path. Use the column for the selected model when specifying switchgear or comparing the available capacity of an existing connection.
- Record the maximum active and apparent power of each unit on the single-line diagram.
- Include existing equipment when checking the agreed export capacity.
Dividing a commercial rooftop between ten trackers
Roof areas with different orientations can use separate trackers. The inverter accepts up to 250 kW of PV input across ten MPPTs. Each tracker has two string inputs, giving twenty inputs in total. The two strings on one tracker share its operating point and its current limit.
Add the operating currents of the parallel strings before checking the 42 A limit per tracker. Check the combined short-circuit current against 55 A as a separate step. Voltage needs a temperature check too. The tracking window is 160 to 1000 V, with start-up at 200 V. The 1100 V maximum is an input limit. Above 1000 V the inverter enters standby and resumes normal operation when the voltage returns to 1000 V.
- Calculate the operating and short-circuit currents for the actual strings on each tracker.
- Use the module temperature coefficients when checking the string voltage range.
Sizing battery power for a measured demand peak
A demand peak has both a magnitude and a duration. The inverter can charge or discharge at up to 124.99 kW. How long the battery can sustain the required output depends on available energy, state of charge and the operating limits of the selected cabinet. Plotting the measured peak against time gives the starting point for choosing the usable capacity.
GoodWe lists GW261.2-BAT-LCD-G10 for this ETR range in its Battery Compatibility Overview V029.1, page 6. The inverter has one battery port, with a nominal voltage of 750 V and a working range of 700 to 1000 V. Its continuous charge and discharge current limit is 178.5 A. A proposed operating point has to satisfy the voltage, current and power limits together.
- Read the required discharge power and duration from the site load trace.
- Record the cabinet model and applicable firmware in the system design.
Backing up critical loads and adding parallel units
Where only selected loads must stay online during an outage, define that circuit separately from the normal grid supply. The ETR datasheet specifies an external STS Box or STS Cabinet for backup. With one inverter it gives a transfer time below 10 ms. Rated and maximum backup apparent power on this model are both 124.99 kVA.
Motor starts and refrigeration loads add a duration constraint. The off-grid peak ratings for this model are 120% for 60 seconds and 150% for ten seconds. Use the continuous rating for normal operation and compare the measured or specified starting demand with the appropriate time window. Allow mounting space for a 98 kg IP66 wall unit and the installation clearances specified for cooling and service.
- List the continuous demand and the starting demand of the critical circuits separately.
- Include transfer equipment and the parallel controller as distinct components of the design.
Documents

Product questions
Is an external STS needed for the ETR backup path?
Yes. The manual states that the inverter can only use the BACK-UP function when paired with STS. The datasheet footnote also states that the STS Box or STS Cabinet is needed. The inverter-to-STS communication cable is included with the unit.
Can PV strings operate in the 1000–1100 V band?
No. For the GW124.99K-ETR-G10, when the input voltage ranges from 1000 V to 1100 V, the inverter enters standby mode. The voltage must return to 1000 V for the inverter to enter the normal operation state.
Compatibility records
| Compatible model | Category | Rating | Status & required accessory |
|---|---|---|---|
| GoodWe GW261.2-BAT-LCD-G10Item number DLK-GOODWE-GW2612BATLCDG10 | Battery Systems | 261.2 kWh | Released [1] |
- GoodWe's Battery Compatibility Overview (p. 6) lists GW261.2-BAT-LCD-G10 in its ETR 80–125 kW column, which covers the GW80K/99.99K/100K/110K/124.99K-ETR-G10 models. The ETR 80–125 kW datasheet (EMEA, p. 2) prints that series; the user manual's single-unit and parallel tables list the battery for the series.
Compare models in this series
| Model | Rated AC output | Max PV input | Phases | MPPT | Battery voltage | Matched batteries | Grid standard | AC limit | Protection |
|---|---|---|---|---|---|---|---|---|---|
| GW80K-ETR-G10 | 80 kW | 160 kWp | 3 | 8 | 700 – 1000 V | 1 | EN 50549 | — | — |
| GW99.99K-ETR-G10 | 99.99 kW | 200 kWp | 3 | 10 | 700 – 1000 V | 1 | — | 99.99 kVA maximum | — |
| GW100K-ETR-G10 | 100 kW | 200 kWp | 3 | 10 | 700 – 1000 V | 1 | — | 110 kVA maximum | — |
| GW110K-ETR-G10 | 110 kW | 220 kWp | 3 | 10 | 700 – 1000 V | 1 | EN 50549 | — | — |
| GW124.99K-ETR-G10 | 124.99 kW | 250 kWp | 3 | 10 | 700 – 1000 V | 1 | — | 124.99 kVA maximum | IP66 |
| GW125K-ETR-G10 | 125 kW | 250 kWp | 3 | 10 | 700 – 1000 V | 2 | — | 137.5 kVA maximum | — |