Description

The GW15K-ETA-G20 is the 15 kW model in GoodWe's ESA G20 series: 15 kW AC, 30 kW PV, charge 15.0 kW at 20.1 A, off-grid 16.5 kVA continuous and 30 kVA for 10 s.

GoodWe ESA GW15K-ETA-G20 (15 kW three-phase power module)

  • 15 kW Three-Phase ESA G20: 15 kW rated AC on 230/400 V, 3L/N/PE, 21.8 A per phase at 400 V.

  • 30 kW Solar PV Input (200% Oversizing): Four 21 A MPPTs take a 30 kW array on this 15 kW hybrid.

  • 16.5 kW Battery Discharge: 20.1 A charge / 22.1 A discharge into 700-950 V BAT-D-G20 storage.

  • 63 A Internal Bypass: Whole-home passthrough on the 5-20 kW class, switching under 4 ms.

Battery discharge is 16.5 kW at 22.1 A

Charge 15.0 kW at 20.1 A, discharge 16.5 kW at 22.1 A, 700-950 V, nominal 750 V, start-up 720 V. One battery input on LFP BAT-D-G20 modules.

30 kW of PV on four 21 A trackers is 200% oversize

Four MPPTs, one string each, 21 A / 26 A Isc, MPPT 120-950 V, start-up 150 V, max 1000 V. 30 kW is the 200% oversize against this 15 kW AC rating.

Off-grid peak is 30 kVA for 10 s

Off-grid 16.5 kVA continuous, 30 kVA for 10 s. Rated backup 15 kVA. Max efficiency 98.1%, European 97.3%. Cooling is Smart Fan Cooling. Bypass stays 63 A here; the 80 A row starts at GW25K.

15 kW ESA G20 power module, 30 kW of PV

ESA Series

15 kW ESA G20 power module, 30 kW of PV

GoodWe's 15 kW ESA G20 power module has 30 kW maximum PV input across four MPPTs. It seats on BAT-D-G20 modules through the documented stacked connector; the IP66 enclosure is 800 × 340 × 270 mm and 34 kg.

Technical data

GoodWe ESA G20 · GW15K-ETA-G20 power module

Rated 3-Phase Power
15 kW
Maximum PV DC input
30 kW
Internal Grid Bypass
63 A
Off-Grid Continuous
16.5 kVA
About these specifications

30 kW maximum PV input and 15 kW rated three-phase AC in the ESA G20 system.

The GW15K-ETA-G20 is the 15 kW three-phase model in the ESA 5–30 kW table. It delivers 15 kW AC, takes 30 kW of PV on four MPPTs, stacks on BAT-D-G20 modules, and holds 16.5 kVA off-grid (30 kVA for 10 s). Internal bypass stays 63 A on this class; 80 A starts at GW25K, not on this model.

Backup switching <4 ms.
Inverter: AC Output & Backup
Rated / max. power
15 kW rated and max (GW15K-ETA-G20). GoodWe ESA G20 series: 5–30 kW
Rated current at 400 V
21.8 A per phase (3L/N/PE, 220/380 V or 230/400 V, 50/60 Hz)
Max. apparent power from grid (passthrough)
43.5 kVA
Backup nominal apparent power
15 kVA
Backup max. apparent power (off-grid)
16.5 kVA continuous (30.0 kVA for 10 s)
Backup max. current (off-grid)
33.4 A
On/off-grid switching time
<4 ms
Power factor / THDi
0.8 leading - 0.8 lagging / THDi <3%

Project fit

Where this model fits.

Scenarios that show which projects the GoodWe ESA GW15K-ETA-G20 (15 kW three-phase power module) belongs in, and the limits behind our engineers' recommendation.

01
Project scenario

15 kW three-phase column on a 30 kW four-tracker roof

15 kW three-phase column on a 30 kW four-tracker roof

A three-phase home plans a PV array of up to 30 kW and needs 16.5 kVA of continuous off-grid backup.

The GW15K-ETA-G20 takes 30 kW of PV on four 21 A MPPTs, discharges the battery at 16.5 kW, and holds 16.5 kVA off-grid (30 kVA for 10 s) on the 63 A internal bypass.

Limits for the configuration
  • PV max 30 kW, 4 MPPTs; battery charge/discharge 15.0/16.5 kW; bypass 63 A; 6 modules per column, 12 per system.

Documents

Product questions

Are the battery base and CT in the standard inverter kit, and are battery modules separate?

Yes. The inverter deliverables include a battery base x 1 and a CT x 1. Battery modules are listed separately under the battery deliverables.

Which BAT-D module has the documented -20°C charging range?

The GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 have a charging temperature range of -20~55 °C.

What backup load can the GW15K-ETA-G20 design support?

The GW15K-ETA-G20 belongs to the first model group of the BACK-UP port off-grid load capacity table, together with the GW5K-ETA-G20, GW6K-ETA-G20, GW8K-ETA-G20, GW9.999K-ETA-G20, GW10K-ETA-G20, GW12K-ETA-G20 and GW20K-ETA-G20, and the GW5K-BTA-G20 to GW20K-BTA-G20 models. For this group the table gives: rated power of a single inductive load 1.1 kVA single-phase and 3.3 kVA three-phase; total rated power of multiple inductive loads 0.4*Pn/3 single-phase and 0.4*Pn three-phase; capacitive load 0.33*Pn/3 single-phase and 0.33*Pn three-phase; half-wave load 2 kW single-phase, with no value given for three-phase.

Compatibility records

The GoodWe ESA datasheet lists GW5.1-BAT-D-G20, GW8.3-BAT-D-G20, GW5.1-BAT-D-G21, GW8.3-BAT-D-G21, GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries. For capacity expansion, including installations that require a lower stack per column, it refers to a battery expansion kit (printed p. 79; PDF p. 80).