Description

On the GW12K-ETA-G20 the stack charges at 12.0 kW / 16.1 A and discharges 13.2 kW / 17.7 A, with 24 kW of PV on four trackers and 13.2 / 24 kVA off-grid.

GoodWe ESA GW12K-ETA-G20 (12 kW three-phase power module)

  • 12 kW Continuous Three-Phase Power: 12 kW rated AC on 230/400 V, 3L/N/PE, with 17.4 A per phase at 400 V.

  • 24 kW Maximum PV Input: Four 21 A MPPTs, one string each, on this 12 kW model.

  • 13.2 kW Battery Discharge: 16.1 A charge / 17.7 A discharge into 700-950 V BAT-D-G20 storage.

  • 63 A Internal Bypass: Whole-home passthrough on this 5-20 kW class, switching under 4 ms.

Battery discharge on this model is 13.2 kW at 17.7 A

Charge 12.0 kW at 16.1 A, discharge 13.2 kW at 17.7 A, 700-950 V, nominal 750 V, start-up 720 V. One battery input on LFP BAT-D-G20 modules.

24 kW of PV lands on four independent 21 A trackers

Four independent MPPTs, one string each, 21 A / 26 A Isc, MPPT 120-950 V, start-up 150 V, max 1000 V. 24 kW is the maximum PV input of this 12 kW model.

Off-grid holds 24 kVA for 10 s

Off-grid 13.2 kVA continuous, 24 kVA for 10 s. Rated backup 12 kVA. Max efficiency 98.1%, European 97.2%. Cooling is Smart Fan Cooling.

12 kW column with 24 kW PV oversizing.

ESA Series

12 kW column with 24 kW PV oversizing.

This 12 kW ESA G20 power module is rated for 24 kW maximum PV input through four MPPTs. The power module seats on a BAT-D-G20 column through the documented stacked connector; its IP66 enclosure is 800 × 340 × 270 mm and 34 kg.

Technical data

High-throughput All-in-One energy management for a 24 kW roof on a 12 kW three-phase column.

Rated 3-Phase Power
12 kW
Maximum PV DC input
24 kW
Internal Grid Bypass
63 A
Off-Grid Continuous
13.2 kVA
About these specifications

24 kW solar capacity with 12 kW continuous three-phase output in a modular column.

Sized as the 12 kW three-phase power stage in the ESA G20 range, the GW12K-ETA-G20 delivers 12 kW AC across three phases and takes 24 kW of PV on four MPPTs. It stacks on BAT-D-G20 modules, charges at 12.0 kW, discharges at 13.2 kW, and holds 13.2 kVA off-grid (24 kVA for 10 s).

Backup switching <4 ms.
Inverter: AC Output & Backup
Rated / max. power
12 kW rated and max (GW12K-ETA-G20). GoodWe ESA G20 series: 5–30 kW
Rated current at 400 V
17.4 A per phase (3L/N/PE, 220/380 V or 230/400 V, 50/60 Hz)
Max. apparent power from grid (passthrough)
43.5 kVA
Backup nominal apparent power
12 kVA
Backup max. apparent power (off-grid)
13.2 kVA continuous (24 kVA for 10 s)
Backup max. current (off-grid)
27.3 A
On/off-grid switching time
<4 ms
Power factor / THDi
0.8 leading - 0.8 lagging / THDi <3%

Project fit

Where this model fits.

Scenarios that show which projects the GoodWe ESA GW12K-ETA-G20 (12 kW three-phase power module) belongs in, and the limits behind our engineers' recommendation.

01
Project scenario

12 kW three-phase column on a 24 kW four-tracker roof

12 kW three-phase column on a 24 kW four-tracker roof

A three-phase house with a PV array of up to 24 kW; its backup needs the 13.2 kVA continuous off-grid rating of this 12 kW column.

The GW12K-ETA-G20 has 24 kW maximum PV input across four 21 A MPPTs and 13.2 kW maximum battery discharge. Off-grid it delivers 13.2 kVA continuous and 24 kVA for 10 s; the 63 A internal bypass is a separate on-grid path rating.

Limits for the configuration
  • PV max 24 kW, 4 MPPTs; battery charge/discharge 12.0/13.2 kW; 6 modules per column, 12 per system.

Documents

Product questions

Does mixing BAT-D capacities change heating or firmware requirements on this 12 kW ESA?

Mixing battery modules of different models is supported. The battery heating film is optional, and only models equipped with the heating film can enable the "Battery Heating" function. The battery heating function is unavailable when GW5.1-BAT-D-G20, GW8.3-BAT-D-G20, GW5.1-BAT-D-G21, GW8.3-BAT-D-G21, GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 are mixed. Do not use batteries without the heating film in low-temperature environments.

What backup load can the GW12K-ETA-G20 design support?

For the BACK-UP port, the rated power of a single inductive load is 1.1 kVA single-phase and 3.3 kVA three-phase. The total rated power of multiple inductive loads is 0.4*Pn/3 single-phase and 0.4*Pn three-phase. Capacitive load is 0.33*Pn/3 single-phase and 0.33*Pn three-phase. Half-wave load is 2 kW single-phase.

Compatibility records

The GoodWe ESA datasheet lists GW5.1-BAT-D-G20, GW8.3-BAT-D-G20, GW5.1-BAT-D-G21, GW8.3-BAT-D-G21, GW6.0-BAT-D-G20 and GW9.0-BAT-D-G20 modules and prints scalability of 12 pcs (p. 3). The user manual limits one column to six batteries. For capacity expansion, including installations that require a lower stack per column, it refers to a battery expansion kit (printed p. 79; PDF p. 80).