The full five-module tower
The five-module LX F16.4-H is the upper single-tower configuration in GoodWe's Lynx Home F table. The set contains the PCU with base, all five modules and the PCU package hardware. It reaches 1090 mm and 244 kg assembled. The stated 16.38 kWh usable energy is a beginning-of-life result at 100% DoD, 0.2C charge/discharge and +25 ± 2 °C, which can vary with the inverter. More modules cannot be added to this tower.
12.80 kW nominal power at 25 A nominal current, with derating depending on temperature and state of charge.
The complete tower in one set
PCU with base and five LX F3.3-H modules.
The largest of GoodWe's four towers
The manual names LX F16.4-H as an applicable five-module model. GoodWe specifies 512.0 V nominal and an operating range of 456.0 to 576.0 V for the assembled tower.

GoodWe Lynx Home F
Compare different models
Scroll sideways to compare every model.

Plan the full tower's route to site
The five-module tower measures 600 × 1090 × 380 mm and weighs 244 kg, putting route and final position into the project plan.

Five is the per-tower limit
GoodWe sets five battery modules as the maximum in one Lynx Home F tower. For more capacity, GoodWe's manual labels the wiring and power-on steps for parallel battery systems as for the Lynx Home F Plus+ series only.

Anchored to floor and wall
The base is fixed with expansion bolts in 8 mm holes, 80 mm deep, and locking brackets hold base and PCU to the wall. The floor must carry the tower weight and be non-flammable.
Technical data
Tower data
- Model
- LX F16.4-H
- Usable energy (per GoodWe)
- 16.38 kWh (100% DoD, 0.2C charge/discharge, +25 ± 2 °C, beginning of lifemay vary with inverter)
- Battery modules
- 5 × LX F3.3-H (102.4 V, 3.27 kWh module energy each)
- Nominal voltage
- 512.0 V
- Operating voltage range
- 456.0 ~ 576.0 V
- Nominal power
- 12.80 (derates with temperature and SOC) kW
- Nominal charge/discharge current
- 25 A
- Assembled size (W × H × D)
- 600 × 1090 × 380 mm
- Assembled weight
- 244 kg
- Cell type
- LFP (LiFePO4)
- Ingress protection
- IP55
- Operating temperature
- Charge 0 to +50; discharge −20 to +50 °C
- Relative humidity
- 0 to 95 %
- Max. operating altitude
- 2000 m
- Communication
- CAN
- Mounting
- Floor-standing, secured to the wall
- Standards (per GoodWe)
- IEC 62619, IEC 62040, CEC (safety)CE, RCM (EMC) · UN38.3 (transport)
Set contents
- Lynx Home F PCU with base
- 1
- LX F3.3-H battery module
- 5
- DC connector set (one positive, one negative connector)
- 1
- Expansion bolts
- 4
- Locking brackets
- 4
- Terminal resistor
- 1
- Screws
- 4 × M5×12, 2 × M5 hexagon, 2 × M6
- Grounding terminals
- 2
- Protection cover
- 1
- Documents
- 1
- Not included
- DC power cable and PE cable (installer-supplied per manual), battery communication cable
Project fit
Where this model fits.
Scenarios that show which projects the GoodWe Lynx Home F LX F16.4-H belongs in, and what to verify before quoting.
The highest single-tower storage step

A project is selecting the largest Lynx Home F configuration listed in GoodWe's four-model table.
At 600 × 1090 × 380 mm and 244 kg, this is GoodWe's five-module single tower. For capacity beyond one tower, GoodWe's manual labels the wiring and power-on steps for parallel battery systems as for the Lynx Home F Plus+ series only.
- 1090 mm assembled height and 244 kg stated weight.
- Five modules is the per-tower maximum.
Documents
GoodWe Lynx Home F Series (HV) Datasheet (EMEA, EN) GoodWe Lynx Home F / F Plus+ User Manual (EN)Product questions
Can a sixth LX F3.3-H go onto this tower?
No, GoodWe's manual sets five modules as the maximum in one Lynx Home F battery system. For more capacity, the manual labels the wiring and power-on steps for parallel battery systems as for the Lynx Home F Plus+ series only, and notes that some models have no COM3 terminal for parallel connection.
Can the LX F16.4-H tower stand outdoors?
Yes, if the place is sheltered. The tower is rated IP55, and GoodWe's manual allows indoor or outdoor installation away from direct sunlight, rain and snow, below 2000 m altitude. Charging needs 0 to +50 °C; discharging works from −20 to +50 °C.
What does the LX F16.4-H set contain?
One Lynx Home F PCU with base and five LX F3.3-H battery modules. The PCU package adds one DC connector set, four expansion bolts, four locking brackets, the terminal resistor, screws, two grounding terminals, a protection cover and documents. The DC power cable, PE cable and battery communication cable are not included.
Compatibility records
GoodWe GW10K-BTItem number DLK-GOODWE-GW10KBTG1 p3 lists assembled LX F6.6-H, F9.8-H, F13.1-H and F16.4-H systems for BT, not the separate LX F3.3-H module. Its footnotes require ARM 19 or later for Lynx Home F and ARM 23 or later for F PLUS+; confirm the system generation before commissioning.
GoodWe GW5K-BTItem number DLK-GOODWE-GW5KBTG1 p3 lists assembled LX F6.6-H, F9.8-H, F13.1-H and F16.4-H systems for BT, not the separate LX F3.3-H module. Its footnotes require ARM 19 or later for Lynx Home F and ARM 23 or later for F PLUS+; confirm the system generation before commissioning.
GoodWe GW8K-BTItem number DLK-GOODWE-GW8KBTG1 p3 lists assembled LX F6.6-H, F9.8-H, F13.1-H and F16.4-H systems for BT, not the separate LX F3.3-H module. Its footnotes require ARM 19 or later for Lynx Home F and ARM 23 or later for F PLUS+; confirm the system generation before commissioning.
GoodWe GW15K-ETItem number DLK-GOODWE-GW15KETG1 p3 lists assembled LX F6.6-H, F9.8-H, F13.1-H and F16.4-H systems for ET 15-30 kW, not the separate LX F3.3-H module. The ARM 07/DSP 06 footnote belongs to Lynx Home F G2, a different generation; verify the applicable F or F PLUS+ firmware for the exact system.
GoodWe GW20K-ETItem number DLK-GOODWE-GW20KETG1 p3 lists assembled LX F6.6-H, F9.8-H, F13.1-H and F16.4-H systems for ET 15-30 kW, not the separate LX F3.3-H module. The ARM 07/DSP 06 footnote belongs to Lynx Home F G2, a different generation; verify the applicable F or F PLUS+ firmware for the exact system.
GoodWe GW25K-ETItem number DLK-GOODWE-GW25KETG1 p3 lists assembled LX F6.6-H, F9.8-H, F13.1-H and F16.4-H systems for ET 15-30 kW, not the separate LX F3.3-H module. The ARM 07/DSP 06 footnote belongs to Lynx Home F G2, a different generation; verify the applicable F or F PLUS+ firmware for the exact system.
GoodWe GW29.9K-ETItem number DLK-GOODWE-GW299KETG1 p3 lists assembled LX F6.6-H, F9.8-H, F13.1-H and F16.4-H systems for ET 15-30 kW, not the separate LX F3.3-H module. The ARM 07/DSP 06 footnote belongs to Lynx Home F G2, a different generation; verify the applicable F or F PLUS+ firmware for the exact system.
GoodWe GW30K-ETItem number DLK-GOODWE-GW30KETG1 p3 lists assembled LX F6.6-H, F9.8-H, F13.1-H and F16.4-H systems for ET 15-30 kW, not the separate LX F3.3-H module. The ARM 07/DSP 06 footnote belongs to Lynx Home F G2, a different generation; verify the applicable F or F PLUS+ firmware for the exact system.
GoodWe GW10K-ETItem number DLK-GOODWE-GW10KETG1 p3 lists assembled LX F6.6-H, F9.8-H, F13.1-H and F16.4-H systems for ET 5-10 kW, not the separate LX F3.3-H module. Its footnotes require ARM 19 or later for Lynx Home F and ARM 23 or later for F PLUS+; confirm the system generation before commissioning.
GoodWe GW5K-ETItem number DLK-GOODWE-GW5KETG1 p3 lists assembled LX F6.6-H, F9.8-H, F13.1-H and F16.4-H systems for ET 5-10 kW, not the separate LX F3.3-H module. Its footnotes require ARM 19 or later for Lynx Home F and ARM 23 or later for F PLUS+; confirm the system generation before commissioning.
GoodWe GW6.5K-ETItem number DLK-GOODWE-GW65KETG1 p3 lists assembled LX F6.6-H, F9.8-H, F13.1-H and F16.4-H systems for ET 5-10 kW, not the separate LX F3.3-H module. Its footnotes require ARM 19 or later for Lynx Home F and ARM 23 or later for F PLUS+; confirm the system generation before commissioning.
GoodWe GW8K-ETItem number DLK-GOODWE-GW8KETG1 p3 lists assembled LX F6.6-H, F9.8-H, F13.1-H and F16.4-H systems for ET 5-10 kW, not the separate LX F3.3-H module. Its footnotes require ARM 19 or later for Lynx Home F and ARM 23 or later for F PLUS+; confirm the system generation before commissioning.