3-pitch solar tracking on a 12 kW three-phase residential inverter.

EcoFlow OCEAN 2 HD-P3-12K0-S2 is the flagship 12 kW three-phase residential hybrid inverter featuring 3 independent 16 A MPPT channels, 200% DC oversizing (24 kWp solar intake), a massive 63 A grid bypass per phase, and true 0 ms online UPS backup, engineered for luxury estates and commercial workshops.

EcoFlow OCEAN 2 HD-P3-12K0-S2 (12 kW three-phase hybrid, 2026 flagship)
  • 12,000 VA Continuous Three-Phase Power (17.4 A)

    Maximum continuous throughput in the OCEAN 2 range, effortlessly running multiple heat pumps and EV chargers.

  • 3 Independent 16 A MPPT Trackers

    Maximum string routing flexibility across 3 distinct roof angles, absorbing up to 24,000 W of solar without generation loss.

  • True 0 ms Seamless Online Three-Phase Backup

    Hardware-level instant transfer ensures zero power interruption during grid failure across all 3 phases.

  • Massive 63 A Grid Bypass per Phase

    Passes through full 63 A utility service currents, powering whole-home panels and heat pumps without sub-panel isolation.

More product details

Built for luxury residential properties and domestic workshops, the HD-P3-12K0-S2 provides 3 independent 16 A MPPT trackers (Isc 20 A), capturing up to 24,000 W of solar generation.

  • 3 MPPT channels allow dedicated tracking for East, South, and West domestic roof planes with zero cross-string clipping.
  • Wide MPPT operating window (200–850 V) optimizes harvest across extreme temperature swings.
  • 200% DC oversizing channels surplus daytime generation directly into high-voltage OCEAN 2 storage.

EcoFlow OCEAN 2 (Three-Phase)

Compare different models

Scroll sideways to compare every model.

Rated AC power
12 kW
6 kW
8 kW
10 kW
Phase
Three-phase
Three-phase
Three-phase
Three-phase
MPPT trackers
3
3
3
3
Max. efficiency
97.8%
97.8%
97.8%
97.8%
Battery voltage
720~960 V
720~960 V
720~960 V
720~960 V
Ingress protection
IP66
IP66
IP66
IP66
Weight
Approx. 36.5 kg
Approx. 36.5 kg
Approx. 36.5 kg
Approx. 36.5 kg
Dimensions
680×203×406.5 (W×D×H) mm
680×203×406.5 (W×D×H) mm
680×203×406.5 (W×D×H) mm
680×203×406.5 (W×D×H) mm
View full technical data
Zero-glitch emergency power with whole-home current pass-through.

Built-in 0 ms solid-state transfer circuitry maintains continuous three-phase power to heat pump controls, server racks, and smart home hubs without voltage sags. True 0 ms seamless transfer prevents memory loss or dropouts on sensitive domestic electronics. Massive 63 A continuous AC bypass contactor per phase eliminates the need to isolate emergency sub-circuits. IP66 cast-aluminum casing certified for clean indoor utility rooms or exposed outdoor walls (-25 to +60 °C).

Holds 13200 VA on this 12 kW box

Watt rating is 12000 W. Apparent power is 13200 VA. The 63 A path stays in the cabinet.

Cascades five inverters on-grid

Off-grid cascade is two. Battery bus is 720 to 960 V. Twelve modules sit on one cabinet.

Reaches 97.8 percent peak conversion

Light-load self-consumption is 50 W. Type II SPD sits on DC and AC.

Technical data

The apex three-phase residential hybrid energy hub engineered for heavy domestic electrification and microgrids.

24 kWp solar capacity with 12 kW continuous output. The maximum OCEAN 2 three-phase throughput.

Maxing out EcoFlow's three-phase hybrid capability, the HD-P3-12K0-S2 delivers 12,000 W continuous AC output (17.4 A max) across 3 balanced phases. With 3 independent MPPT trackers, 63 A grid bypass per phase, and true 0 ms UPS transfer, it provides commercial-grade power for large domestic estates, luxury residences, and agricultural outbuildings.

Continuous 3-Phase Power
12,000 VA
200% Solar DC Intake
24,000 Wp
Multi-Pitch Routing
3 MPPTs
Heavy Grid Bypass
63 A / Phase
Inverter: PV Input
MPP trackers / strings
3 MPPTs, 1 string per MPPT
Max. input power per MPPT
8 kW
Max. total PV input power
24 kW (12 kW model).Family: 6K=12,000 / 8K=16,000 / 10K=20,000 / 12K=24 kW
Max. input voltage
1,000 V
PV operating voltage range
50–1,000 V; MPPT range at rated power 500–850 V
MPPT start-up voltage
120 V (low start-up, begins generating earlier in the day)
Max. input / short-circuit current per MPPT
16 A / 20 A
Inverter: AC Output & Backup
Rated output power (on-grid)
12 kW (12 kW model). Family: 6,000 / 8,000 / 10,000 / 12 kW
Max. apparent power
13.2 kVA (12 kW model).Family: 6,600 / 8,800 / 11,000 / 13.2 kVA
Nominal / max. output current
17.4 A @230 V nominal; max. 21.4 A (12 kW model)
Grid connection
Three-phase 3L+N+PEL-L 380/400 V, L-N 220/230 V · 50/60 Hz · TN-S, TN-C, TN-C-S, TT systems
Max. AC input current (whole-home bypass)
63 A, integrated whole-home backup, no external backup box
Backup (off-grid) output
12 kW nominal (12 kW model)THDu ≤2% · 100% unbalanced load support
Switchover time (grid↔off-grid)
0 ms load-side, both directions (per EcoFlow conditions: compliant, stable gridload below rated backup output)
Power factor / THDi
0.8 leading – 0.8 lagging; THDi ≤3% at full load
Parallel installation
Up to 5 cascaded inverters on-gridup to 2 cascaded off-grid
Battery Interface & Storage Scaling
Battery bus
800 V rated; 720–960 V range; CAN communication
Max. battery capacity per inverter
Up to 12 OCEAN 2 battery modules (up to 60 kWh with one inverter)
Stack rules
5 kWh (BD-5-S2) or 8 kWh (BD-8-S2) modules: max 6 per floor-standing stack / 3 wall-mountedmixed OCEAN 2 + PowerOcean gen-1 stacking capped at 4 per stack · >4 packs per stack requires local-regulation and firmware check
Module performance
5.02 kWh nominal / 4.85 kWh usable per BD-5-S23.4 kW discharge, 2.5 kW charge, 4.08 kW max discharge (≥20 min) per module
Cross-generation compatibility
Works with EcoFlow PowerOcean gen-1 batteries and inverters (hybrid stacking supported)
Efficiency & Protection
Max. efficiency
97.8%
Self-consumption (light load)
50 W (measured <300 W total load, lab conditions)
Integrated protections
GFCI, AFCI, PV insulation resistance detection, anti-islanding, PV reverse-polarity protection, emergency power off (EPO), AC over-current / short-circuit / over-voltage protection
Surge protection
Type II DC + Type II AC SPD integrated
General
Ingress protection / environment
IP66; outdoor/indoor; relative humidity 0–100%
Operating temperature
-20 °C to +60 °C (derating above 40 °C)storage -30 °C to +60 °C · altitude up to 3,000 m (derating above 2,000 m)
Communication / UI
Bluetooth, WiFi, RS485, CANLED + EcoFlow app (Pro app for installers)
Dimensions / weight (inverter)
680 × 203 × 406.5 mm (W×D×H)approx. 36.5 kg · floor stand or wall mounted · anti-theft supported
Warranty
15 years on inverter and battery (capacity-retention terms per EcoFlow warranty policy)
Packaging (VPE)
1 per carton, 8 per pallet

Project fit

Where this model fits.

Scenarios that show which projects the EcoFlow OCEAN 2 HD-P3-12K0-S2 (12 kW three-phase hybrid, 2026 flagship) belongs in, what to verify before quoting, and when another model is the better pick.

01
Project scenario

Large Luxury Estates & Agricultural Workshops (16–24 kWp PV) with Heavy Electrification

Large Luxury Estates & Agricultural Workshops (16–24 kWp PV) with Heavy Electrification

Three-phase detached estates equipped with multi-zone air-to-water heat pumps, pool heating, and dual EV chargers across 3 distinct roof aspects.

12 kW continuous AC throughput provides the power needed to run heavy loads simultaneously, while 24 kWp solar intake ensures fast battery replenishment on short winter days.

  • BoundaryIf total solar array size is under 16 kWp and continuous household load stays under 8–10 kW, step down to the HD-P3-8K0-S2 or HD-P3-10K0-S2. ---
What Linker confirms with you
  • If total solar array size is under 16 kWp and continuous household load stays under 8–10 kW, step down to the HD-P3-8K0-S2 or HD-P3-10K0-S2. ---

Documents

EcoFlow OCEAN 2 Three-Phase Hybrid Inverter Datasheet Datasheet · PDF · EN EcoFlow OCEAN 2 Three-Phase Installation Guide (EN/DE) Manual · PDF · EN

Product questions

What size AC circuit breaker is required for the HD-P3-12K0-S2?

3-pole 25 A or 32 A MCB; 5 × 4 mm² to 5 × 6 mm² copper cable. The HD-P3-12K0-S2 delivers a nominal continuous output current of 17.4 A per phase (at 400 V three-phase). A 3-pole 25 A or 32 A miniature circuit breaker (MCB) is standard on the AC distribution board.

System components

Required components

EcoFlow OCEAN 2 LFP Battery 5.02 kWh (BD-5-S2)

Item number: DLK-ECOFLOW-EFBD5S2

The OCEAN 2 is a battery-based system: at least one OCEAN 2 LFP module is required for storage, backup and HEMS operation. Each 5.02 kWh module (4.85 kWh usable) delivers 3.4 kW discharge / 2.5 kW charge and stacks wire-free under the inverter.

View product

EcoFlow OCEAN 2 LFP Battery Base

Item number: DLK-ECOFLOW-OCEAN2-BASE

Every floor-standing battery tower sits on the OCEAN 2 battery base with adjustable levelling feet, spirit level and click-on stacking terminal, the standard mounting for up to 6 modules per stack (wall mounting up to 3 modules uses wall brackets instead).

View product
Recommended components

EcoFlow OCEAN 2 LFP Battery 8 kWh (BD-8-S2)

Item number: DLK-ECOFLOW-EFBD8S2

The larger 8 kWh module reaches higher capacity in fewer stacking steps, same tower format, up to 6 per floor stack and 12 modules per three-phase inverter per EcoFlow's compatibility matrix.

View product

EcoFlow Smart Meter (external grid-point meter)

Item number: DLK-ECOFLOW-SMART-METER

Only needed when not all household loads are wired behind the backup output: the external meter then provides the grid import/export measurement the HEMS needs for self-consumption optimisation and export limiting. In the standard whole-home-backup topology the built-in meter covers this.

View product
Optional components

EcoFlow Battery Junction Box

Item number: DLK-ECOFLOW-EFBDJCS1

For multi-tower installations: cascaded battery stacks connect through a junction box (built-in 1500 V DC / 32 A fuse, battery switch, B-COM port); up to 3 junction boxes can run in parallel. Not needed for a single integrated stack under the inverter. Confirm the OCEAN 2-compatible junction-box variant when ordering.

View product

EcoFlow Battery Stack Bridge

Item number: DLK-ECOFLOW-STACK-BRIDGE

Bracket for dual-tower battery systems: rigidly ties two adjacent towers together (base spacing 94.6-104.5 mm for OCEAN 2 bases). EcoFlow recommends securing both sides of each battery unit, 12 brackets for two 6-module towers, and seismic restraint in seismic zones.

View product

EcoFlow PowerOcean LFP Battery 5.1 kWh (BD-5.1-S1, gen 1)

Item number: DLK-ECOFLOW-EFBD51S1

Cross-generation expansion path: existing PowerOcean gen-1 packs can be mixed with OCEAN 2 packs in one system (max 4 modules per stack in mixed use per the matrix), useful when extending a gen-1 install instead of replacing it.

View product

Approved pairings