EzManager3000 is the home energy manager: one DIN-rail gateway that ties a hybrid inverter, a grid-tied inverter, up to two EV chargers, an SG-Ready heat pump and up to twelve Shelly smart plugs into a single schedule.

  • SEC1000S: export power control and parallel control for up to 10 ET 5-10 kW inverters, with a built-in GM3000 meter.
  • SEC3000C: parallel connection for GoodWe on-grid and hybrid inverters, up to 60 (RS485) / 10 (LAN) units, with a built-in GM330 meter — no separate meter or 4G router needed.
  • EzLogger3000C: C&I data acquisition and protocol conversion for up to 100 mixed old/new inverters.
  • EzManager3000: single-site smart home EMS controlling up to 1 hybrid inverter, 2 EV chargers, 1 heat pump and 12 Shelly devices.
IP20
Ingress protection
Manufacturer
GoodWe
Model code
EzManager3000
Item no.
DLK-GOODWE-EZMANAGER3000
Delivery
Delivery to Germany · EUR 14.90 at checkout
Orderable · lead time confirmed after order

Plan with EzManager3000

New system, extension or replacement? Linker Advisor starts from this article and asks only for what is still open — existing model, quantity, postcode, installation date.

Figures transcribed from the manufacturer datasheet on file. Confirm your grid code and configuration with our engineers before ordering.

  • GoodWe · SAJ · Pylontech · EcoFlow · Chint paired from the maker’s own lists
  • Datasheets on file for every item
  • Within 24 h engineering response
  • MOQ 1 unit Â· EU delivery
  • Engineering-checked configurations
EzManager3000, specified from the datasheet.
System logic

EzManager3000, specified from the datasheet.

Every value on this page is transcribed from the manufacturer documentation on file.

SEC1000S: export power control and parallel control for up to 10 ET 5-10 kW inverters, with a built-in GM3000 meter.
SEC3000C: parallel connection for GoodWe on-grid and hybrid inverters, up to 60 (RS485) / 10 (LAN) units, with a built-in GM330 meter — no separate meter or 4G router needed.
EzLogger3000C: C&I data acquisition and protocol conversion for up to 100 mixed old/new inverters.
In pictures

Inspect it before you spec it.

Official renders, installation photos and system panels for this model line.

Manufacturer render.
Product

Manufacturer render.

Documentation

Specifications

Every value exactly as published in the official EzManager3000 documentation.

DC power supply (V)12
Packaging (VPE)1 per carton, 240 per pallet
Hybrid inverters supportedUp to 1
Grid-tied inverters supportedUp to 1
EV chargers supportedUp to 2
Heat pumps supportedUp to 1 (SG-Ready)
Shelly devices supportedUp to 12
Network interfacesLAN, Wi-Fi 802.11 b/g/n and Bluetooth 5.2
Field interfaces4 × RS485, 4 × DI, 2 × DO, 1 × CAN and 1 × AI
ProtocolsModbus-TCP over Ethernet; Modbus-RTU over RS485
Power supply100–240 V AC, 50/60 Hz; 12 V DC output
Mounting optionsWall, DIN rail or tabletop
Power consumption≤7 W
Dimensions99 × 85.6 × 71 mm
Weight0.2 kg
Operating temperature-30 to +60 °C
Ingress protectionIP20
Full datasheet (PDF) Ask an engineer

Documents

GoodWe EzManager3000 datasheet (EN)ENDownload
Missing a certificate or language version?Request a document

Pick the rating

GoodWe family. Same engineering, different size.

4 ratings Same series, same engineering — your model is highlighted.
GoodWe SEC1000S Sign in for pricing
GoodWe EzLogger3000C Sign in for pricing
GoodWe EzManager3000 HEMS Gateway This model Sign in for pricing
Ingress protection
IP65
IP66
IP20
IP20
Weight
6 kg
≤16.9 kg
0.8 kg
0.2 kg
Dimensions
350 × 460 × 143 mm (W×H×D)
450 × 400 × 242 mm (W×H×D)
255 × 47.5 × 173 mm (W×H×D)
99 × 85.6 × 71 mm (W×H×D)

Every figure comes straight from the manufacturer's official datasheet.

Configuration 3

Four different roles; pick by plant size and what you are controlling.

  • SEC1000S: export power control and parallel control for up to 10 GoodWe storage inverters, with EzLogger Pro, GM3000 meter and CT adapter built in.
  • SEC3000C: C&I cabinet for up to 60 inverters over RS485 (20 per port) or 10 over LAN, with a GM330 meter and EzLogger3000C pre-wired.
  • EzLogger3000C: the logger alone, up to 100 connected devices, for control panels you build yourself.
  • EzManager3000: residential HEMS gateway for one hybrid inverter plus EV chargers and a heat pump.

They share one chassis and one datasheet but serve different plants, so check the suffix before ordering.

  • SEC1000S: storage variant, parallel control of up to 10 GoodWe ET / ET PLUS+ hybrids.
  • SEC1000: on-grid variant for string-inverter plants, up to 60 inverters.
  • Label: the storage unit is printed 'Storage Only' on the housing.
  • Mixed C&I plants: the SEC3000C supports mixed parallel of C&I hybrid and grid-tied inverters from ARM 04.

Yes, that is its role: it supports an on-grid inverter and a storage inverter running in parallel, so the existing PV keeps working while storage and flexible loads are added.

  • Devices: up to 2 EV chargers, 1 SG-Ready heat pump and 12 Shelly devices, scheduled together in the SEMS+ app.
  • Tariffs: dynamic and negative electricity tariffs are supported, with auto-connection to trading platforms and AI-optimised, habit-based scheduling per GoodWe.
  • Hardware: DIN-rail gateway on a 12 V DC supply; GoodWe lists a 100 to 240 V power adapter for it.

Installation & wiring 1

Meter and logger are built in; per GoodWe's datasheet the current transformers for the SEC1000S are not.

  • CTs: the SEC1000S takes compatible nA:5A CTs that are not supplied; budget them with the unit.
  • Power: the SEC1000S accepts 60 to 280 Vac; the SEC3000C 100 to 240 V; consumption is 10 W and 25 W or less respectively.
  • Mounting: the SEC1000S is IP65 for wall, bracket or pole mounting at -25 to +60 C; the SEC3000C is an IP66 wall-mounted cabinet rated -30 to +60 C.

Operation & warranty 1

Protocol conversion is the EzLogger3000C's job, whether inside the SEC3000C cabinet or on its own.

  • Northbound: Modbus-TCP and IEC 60870-5-104 over Ethernet; Modbus-RTU on the four RS485 ports.
  • Capacity: up to 100 connected devices, counting meters, ripple-control receivers and PT100/PT1000 sensors, not only inverters.
  • Monitoring: the SEC3000C reports to the SEMS portal and a third-party system simultaneously, with third-party control over Modbus.
  • I/O: 4 DI, 2 DO and 4 AI on the logger for plant signals.

Availability & compliance 1

GoodWe lists radio and cybersecurity certificates for the SEC3000C, EzLogger3000C and EzManager3000.

  • SEC3000C and EzManager3000: CE-RED (EN18031) and RCM.
  • EzLogger3000C: CE-RED (EN18031), RCM, FCC, ISED, Anatel, KC, MIC, VCCI and WPC, plus ETSI EN 303 645 cybersecurity compliance.
  • Grid code: grid-connection certificates sit with the inverters, not the controller; confirm the complete certificate set for your project with the quote.
Next step

Send the project. Hear from an engineer within 24 hours.

Loads, tariff, site constraints - our engineers reply with a compatibility check and a sizing recommendation.

Contact project support

Or write to linker01@de-linker.com — attach your load profile if you have one.