Description
4.6 kW on AC. Two MPPT routes on the roof.
EF HD-P1-4K6-S2 is the 4,600 W model of the EcoFlow OCEAN 2 single-phase hybrid range. Two MPPT channels take up to 10,600 W of PV; 10,600 W is the PV input limit, not the AC power delivered to the house.
AC side
4,600 W rated on-grid output and 4,600 VA at the separate BACKUP output.
Two MPPT channels
18 A maximum input current on a single PV input, 16 A on a dual PV input; MPPT voltage range 90–520 V.
IP65, 21.5 kg, 679.6 × 182.7 × 280 mm without the IOT and 4G dongle; natural convection.
More product details
Rated on-grid output is 4,600 W. On the PV side, two MPPT channels and a 10,600 W maximum shape the string plan without turning this into a 10,600 W AC inverter.
- MPPT range 90–520 V; maximum PV input 600 V.
- 18 A per MPPT on a single PV input, 16 A on a dual PV input.
- BACKUP output 4,600 VA; the connected circuits follow the system design.
Two MPPT channels at 4.6 kW AC
Rated on-grid output is 4,600 W. The PV side allows 10,600 W maximum, with two MPPT channels and a 90–520 V MPPT window.
A separate BACKUP output
BACKUP maximum output is 4,600 VA. The circuits wired to that output are the backup side; this rating is not a whole-house continuity promise.
WLAN, Bluetooth, WAN and optional 4G
Communication is RS485, CAN, WLAN, Bluetooth, WAN and 4G. The IOT dongle in the carton is configured at commissioning; the 4G dongle is optional.
Technical data
OCEAN 2 single-phase · 4.6 kW AC
Two MPPT channels on a 4.6 kW single-phase inverter.
EF HD-P1-4K6-S2 is 4,600 W rated AC, with 10,600 W maximum PV input and two MPPT channels.
- Rated AC output
- 4,600 W
- MPPT channels
- 2
- Max. PV input
- 10,600 W
DC input (PV)
- Model
- EF HD-P1-4K6-S2
- Maximum PV power
- 10.6 kW
- Maximum input voltage
- 600 V
- MPPT voltage range
- 90–520 V
- Maximum input current per MPPT
- 18 (single PV input), 16 (dual PV input) A
- Maximum short-circuit current per MPPT
- 20 A
- Number of MPPTs
- 2
DC input (battery)
- Rated voltage
- 790 V
- Maximum voltage
- 800 V
- Rated current
- 7.6 A
- Maximum current
- 7.6 A
AC output (on-grid) and BACKUP
- Grid connection
- L+N+PE220/230/240 V
- Rated output power (on-grid)
- 4.6 kW
- Maximum apparent power (on-grid)
- 4.6 kVA
- Rated output current (on-grid)
- 20 A
- Maximum output current (on-grid)
- 23 A
- BACKUP maximum output power
- 4.6 kVA
- Nominal frequency
- 50/60 Hz
- THD (at rated power)
- ≤3%
- Power factor
- 0.8 leading ~ 0.8 lagging
Device data
- Maximum efficiency
- >96.5%
- European weighted efficiency
- >96%
- Ingress protection
- IP65
- Weight
- 21.5 kg
- Dimensions (W × D × H)
- 679.6 × 182.7 × 280 mmwithout IOT and 4G dongle
- Operating temperature
- −20 to 50 °Cderating above 40 °C or below 0 °C
- Communication
- RS485 & CAN & Wi-Fi & Bluetooth & WAN & 4G
- Grid-connection certificate
- EN 50549-1:2019+A1:2023 / EN 50549-10:2022DEKRA Certificate of Conformity 4951182.02COC, 24 March 2026, expires 24 March 2031
Project fit
Where this model fits.
Scenarios that show which projects the EcoFlow OCEAN 2 HD-P1-4K6-S2 (4.6 kW single-phase hybrid) belongs in, and the limits behind our engineers' recommendation.
A single-phase connection at 4.6 kW AC
The project has a single-phase grid connection and does not need a higher AC rating.
Two MPPT channels and a 10,600 W PV limit sit on a 4,600 W AC rating. GRID connection is L+N+PE at 220/230/240 V.
- Two MPPT channels; 10,600 W maximum PV input.
- 4,600 W on-grid; 4,600 VA BACKUP.
- String voltage and current, the local grid type (TN-S, TN-C, TN-C-S or TT) and the BACKUP circuits set the design.
Documents
OCEAN 2 Single-Phase Hybrid Inverter Datasheet (EN) OCEAN 2 Single-Phase Hybrid Inverter User Manual V1.3 (DE) OCEAN 2 Single-Phase Installation Guide V1.7 (DE) OCEAN 2 Single-Phase brochure (EN) DEKRA Certificate of Conformity 4951182.02COC (EN 50549-1/-10)Product questions
Which circuits receive power through the HD-P1-4K6-S2 BACKUP connection?
The unit has a dedicated BACKUP output rated 4,600 VA. The circuits wired to that output form the backup side; other building circuits are not made backup circuits by the inverter rating alone.
How many of these inverters can be cascaded?
Up to three EF HD-P1-(3K/3K68/4K6/5K/5K75/6K)-S2 units can be cascaded. Each cascaded inverter has its own RCD.
Is the IOT dongle required?
The EcoFlow IOT-Dongle ESS is in the inverter carton and must be configured. A 4G dongle ESS (EU) is optional and obtained separately.
System components
Recommended components
EcoFlow IOT-Dongle ESS
The inverter carton includes the IOT dongle; it must be configured at commissioning.
Optional components
OCEAN 2 LFP Battery EF BD-5-S2
Item number: DLK-ECOFLOW-EFBD5S2
The family datasheet includes EF BD-5-S2. The German installation guide’s battery chapter is written for EcoFlow PowerOcean LFP-Akku; confirm the layout for this inverter before the order.
OCEAN 2 LFP Battery EF BD-8-S2
Item number: DLK-ECOFLOW-EFBD8S2
The family datasheet includes EF BD-8-S2. The German installation guide’s battery chapter is written for EcoFlow PowerOcean LFP-Akku; confirm the layout for this inverter before the order.
EcoFlow 4G-Dongle ESS (EU)
Optional. Obtained separately.